Coalbrookdale MUCH WENLOCK Installation Instructions Manual

Freestanding stove with boiler

Advertisement

THE MUCH
WENLOCK
Consumer Protection Act 1987
As manufacturers and suppliers of cooking and heating products, in
compliance with Section 10 of the Consumer Protection Act 1987,
we take every care to ensure, as far as is reasonably practicable, that
these products are so designed and constructed as to meet the
general safety requirement when properly used and installed. To this
end, our products are thoroughly tested and examined before
despatch.
IMPORTANT NOTICE: Any alteration that is not approved by Aga-
Rayburn could invalidate the approval of the appliance, operation of
the warranty and could also affect your statutory rights.
Control of Substances - Health and Safety
Important
This appliance may contain some of the materials that are indicated
below. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when
RATING
kW
Direct Space Heating
Btu/h
kW
Water Heating
Btu/h
NOTE: THERE ARE TWO SETS OF BACK OUTLET
'FLOW AND RETURN' CONNECTIONS ON THE L.H. OR
R.H. SIDE OF THE BOILER. THE STOVE CAN BE
INSTALLED AS A TOP OR BACK FLUE OUTLET
APPLIANCE.

Installation Instructions

for Freestanding
Much Wenlock Stove
with Boiler
Top Flue
Rear Flue
Outlet
Outlet
4.3
3.9
14,500
13,500
6.1
7.3
21,000
25,000
handling where applicable, the pertinent parts that contain any of the
listed materials that could be interpreted as being injurious to health
and safety, see below for information.
Firebricks, Fuel beds, Artificial Fuels - when handling use
disposable gloves.
Fire Cement - when handling use disposable gloves.
Glues and Sealants - exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil - may be harmful if inhaled, may be irritating to skin,
eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water spray,
ensure that parts are securely wrapped.
WARNING
BOILER MODEL
UNDER NO CIRCUMSTANCES MUST THE
APPLIANCE BE FIRED DRY AS DAMAGE WILL OCCUR
The maximum room size (of normal construction) and
radiator surface that can be heated are:
m
Direct Space Heating
ft
Pipe and Radiator Surface
m
(no domestic hot water)
ft
Radiator Surface
m
(with domestic hot water)
ft
Top Flue
Rear Flue
73.6
67.9
3
2600
2400
3
12.2
14.5
3
131.25
156.25
3
9.9
12.2
3
106.25
131.25
3
04/04 EINS 33744

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUCH WENLOCK and is the answer not in the manual?

Questions and answers

Summary of Contents for Coalbrookdale MUCH WENLOCK

  • Page 1: Installation Instructions

    Installation Instructions THE MUCH for Freestanding Much Wenlock Stove WENLOCK with Boiler handling where applicable, the pertinent parts that contain any of the Consumer Protection Act 1987 listed materials that could be interpreted as being injurious to health As manufacturers and suppliers of cooking and heating products, in and safety, see below for information.
  • Page 2: Hot Water System

    175mm diameter minimum moisture and acid resistant liners to BS 1181 or precast linings as specified in the The Much Wenlock Stove with Boiler is intended to current Building Regulations and requirement in BS 6461 provide space heating and the heating of domestic hot Part 1 and BS 7566 Parts 1 to 4 should be observed.
  • Page 3: Air Supply

    Chimney Terminations All chimney should terminate above roof level in accordance with current Building Regulations Section J/1/2/3 and as outlined in BS 6461 Part 1 and BS 7566 Parts 1 to 4. However well designed, constructed and positioned, the satisfactory performance of a flue can be adversely affected by the downdraughts caused by adjacent tall buildings and trees or even a nearby hills.
  • Page 4: Installation

    PROVISION MUST ALWAYS BE MADE FOR SWEEPING THE CHIMNEY. IMPORTANT: CEMENT PIPES AND FITTINGS MUST NOT BE USED WITHIN 2m OF THE STOVE OUTLET CHIMNEYS OF PLAIN PIPE ARE NOT RECOMMENDED BUT CERTAIN PROPRIETARY MAKES OF INSULATED CHIMNEY ARE SUITABLE. INSTALLATION Handle the firedoor with care to ensure the glass panel remains intact.
  • Page 5: General Information

    TESTING AFTER COMMISSIONING After completing the installation, the Heating Contractor should demonstrate to the user, the operation of the fire, e.g. ashpit door, spinwheel setting, the method of riddling as well as the routine flue cleaning method. Ensure the Operating Instructions are left in the possession of the user.
  • Page 8 For further advice or information contact your local distributor/stockist With Aga-Rayburn’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time. Manufactured By Aga-Rayburn Station Road Ketley Telford Shropshire TF1 5AQ England...

Table of Contents