  • Page 1 WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.
  • Page 2 OPTION OPTION windows and doors if required. The Coalbrookdale GS1i has one access door as part of its design. The glass fronted door is for access to the coals and apart from initial commissioning of the stove, or in case the pilot is required to be lit with a taper due to malfunction of the spark ignition system.
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS The installation of the appliance must be in accordance with the relevant requirements of the Gas Safety (Installation and Use) Regulations 1984 (as amended), Building Regulations and the Building Standards (Scotland) (Consolidation) Regulations. It should be in accordance also with any relevant requirements of the local Gas Region and Local Authority, and the relevant recommendations of the following current British Codes of Practice &...
  • Page 4: Air Supply

    THE FLUE - See fig 1a/1b AIR SUPPLY The stove may be connected to an existing masonry The stove does not normally require any additional chimney with a cross sectional dimension not less than purpose made ventilation. 175mm. or a lined masonry chimney to BS.6461 Part 1. or a pre-cast flue block chimney to BS,1289 or BS.6461 or chimneys which have been approved to the relevant British Standards as being suitable for use with solid fuel...
  • Page 5: Gas Connection

    GAS CONNECTION CLOSURE PLATE The complete installation must be tested for soundness The closure plate must always be fitted as in Fig. 1C with and purged as described in BS. 6891. the four rawlplugs, screws and decorative caps supplied. Adhesive tape or other sealing material which is suitable The gas inlet to the stove is 8mm dia compression, and for the type of surface may be used.
  • Page 6 LAYING THE FUEL BED Open the door of the stove (Using the tool supplied). See Fig. 2. Pour the aggregate into the burner tray as illustrated in Fig. 3. Fit the coal guard as illustrated in Fig. 3. Do not compress or tap down. Any excess should be kept and handed to the user for future use.
  • Page 7 LAYING THE FUEL BED FIG. 3 FIG. 4 FIG. 5...
  • Page 8 FIG. 6 FIG. 7 FIG. 8...
  • Page 9: Commissioning And Testing

    tool supplied). COMMISSIONING AND TESTING NO SMOKING OR NAKED LIGHTS The whole installation must be inspected and tested for soundness, and purged up to the gas service cock in accordance with BS.6891. Remove the pressure test point sealing screw on the burner feed pipe, located at the left hand side of the control valve, connect a suitable pressure gauge.
  • Page 10 TO LIGHT THE STOVE If the pilot is not alight, follow procedure to light pilot. FIG. 13 Turn the control knob anti-clockwise until the full on position ( ) (See Fig. 13). The main burner will light. At this setting the pressure should be 17.7+/-1.0mbar with an inlet pressure of 20mbar for natural gas or 36 +/- 1.0mbar with an inlet pressure of 37mbar for propane.
  • Page 11 CHECK FOR CLEARANCE OF INSTRUCT USER PRODUCTS OF COMBUSTION Ensure that all doors and windows of the room are Hand over all the instructions to the user and explain how closed. to light and operate the appliance. Light the stove as described. leave on maximum rate for Impress upon the user that the coals must be located in 5 minutes.
  • Page 12: Servicing And Replacement Parts

    SERVICING AND REPLACEMENT PARTS FIG. 20...
  • Page 13: Servicing Procedure

    SERVICING It is recommended that the stove is inspected/serviced annually by a competent person (e.g. A Corgi Registered Installer). It is recommended that the flue is checked for debris. After any servicing ALWAYS check for gas soundness and carry out a spillage test as detailed in the section ‘CHECK CLEARANCE PRODUCTS...
  • Page 14: Replacement Of Parts

    REPLACEMENT OF PARTS Ensure the stove is cold. Pilot Assembly Isolate the gas supply to the stove. Disconnect the feed pipe at the pilot assembly. On completion ALWAYS check for gas soundness. Disconnect the thermocouple connection at the control valve and pull off the ignition lead from the electrode. Hands should be washed after handling coals.
  • Page 15: Fault Finding Chart

    FAULT FINDING CHART...
  • Page 16: Short List Of Spare Parts

    SPARE PARTS SHORT LIST OF SPARE PARTS The following Spare Parts are available from your Distributor: DESCRIPTION MAKERS PART NUMBER Gas Valve - NG HG4M410130 - PROPANE HG4M410131 Pilot Assembly - NG FG4M420330 - PROPANE FG4M420335 Burner Injector - NG HG4M410128 - PROPANE HG4M410129...
  • Page 17 Installation & Servicing Instructions Little Wenlock Gas (GS1i) - Top Rear Open Flue & Closure Plate Model AMENDMENT SHEET REF: EINS 510877 (TOP REAR OPEN FLUE MODEL) - PAGE 7 (Fig. 8) EINS 510878 (CLOSURE PLATE MODEL) - PAGE 7 (Fig. 8) DELETE ILLUSTRATION AND REPLACE WITH: Fig.
  • Page 18 For further advice or information contact your local distributor/stockist With Aga-Rayburn’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time. Manufactured By Aga-Rayburn Station Road Ketley Telford Shropshire TF1 5AQ www.aga-rayburn.co.uk...

Table of Contents