Inspection and Adjustment of Body back
"0" positioning of the dial gauge
Surface plate
①  Put the tool (J18001-1) on the surface plate, and set the dial gauge to "0".
②  Turn the index ring to shift the position by "0.42 mm" from "0" that was set in ① .
(This position is "0" of D50.)
③  Measure the body back based on "0" reference position of the index ring.
Measure 4 parts from the bayonet face to the CCD-PCB
attaching face.
 
Standard:48.25±0.015mm/ Parallelism: within 0.015mm
In case it is out of standard, make an adjustment
by loosening screws that attach the front and rear bodies,
by putting the washer(s) on the contact surface be-
or
tween the front body and rear body.
Note: For some bodies, washer(s) are already put on the attaching face of the CCD-bracket.
There are 2 cases as follows.
  1. Purpose : To adjust the height of the camera body
There are indications(color mark) on the camera body side of the CCD-PCB attaching face.
    {Blue =0.02mm (#87), Red = 0.1mm (#88), Green = 0.06mm (#89)}
* By adding the measured value to the thickness of washers, check if it is within the standard
(48.25±0.015mm).
  2. Purpose : To adjust the height of the CCD bracket
   There are indications(color mark) of the CCD-bracket attaching face
    { Red 2 lines = 0.02mm (#87), Red 1 line = 0.1mm (#88)}
   * When the CCD PCB is replaced, remove the washers.