Inspection and Adjustment of Body back
"0" positioning of the dial gauge
*
Surface plate
① Put the tool (J18001-1) on the surface plate, and set the dial gauge to "0".
② Turn the index ring to shift the position by "0.42 mm" from "0" that was set in ① .
(This position is "0" of D50.)
③ Measure the body back based on "0" reference position of the index ring.
Measure 4 parts from the bayonet face to the CCD-PCB
・
attaching face.
Standard:48.25±0.015mm/ Parallelism: within 0.015mm
In case it is out of standard, make an adjustment
・
by loosening screws that attach the front and rear bodies,
by putting the washer(s) on the contact surface be-
or
tween the front body and rear body.
Note: For some bodies, washer(s) are already put on the attaching face of the CCD-bracket.
There are 2 cases as follows.
1. Purpose : To adjust the height of the camera body
There are indications(color mark) on the camera body side of the CCD-PCB attaching face.
{Blue =0.02mm (#87), Red = 0.1mm (#88), Green = 0.06mm (#89)}
* By adding the measured value to the thickness of washers, check if it is within the standard
(48.25±0.015mm).
2. Purpose : To adjust the height of the CCD bracket
There are indications(color mark) of the CCD-bracket attaching face
{ Red 2 lines = 0.02mm (#87), Red 1 line = 0.1mm (#88)}
* When the CCD PCB is replaced, remove the washers.
0" position of D50
- A22 ・
-
VBA12001-R.3668.A
Measuring points