Auxiliary Heat Ratings - Heat Controller Geothermal Installation Instructions Manual

Geothermal heat pump systems

Advertisement

Heat Controller, Inc.
Heat Controller, Inc.
Heat Controller GeoMax 2
Tranquility 27™ (TT) Series
Tranquility 27™ (TT) Series
Auxiliary Electric Heat
Auxiliary Electric Heat
Auxiliary Electric Heat

Auxiliary Heat Ratings

Auxiliary Heat Ratings
Auxiliary Electric
Heat Model
Auxiliary Electric
Heat Model
HGM5A
AGM5A
AGM5A
HGM8A
AGM8A
AGM8A
HGM10A
AGM10A
AGM10A
HGM12A
AGM12A
AGM12A
HGL10A
AGL10A
AGL10A
HGL15A
AGL15A
AGL15A
HGL20A
AGL20A
AGL20A
Grey area denotes compatibility
Note: Horizontal units rated for zero clearance unit and 1" clearance for the first three feet of duct,
Note: Vertical units rated for zero clearance for both unit and duct.
Grey area denotes compatibility
vertical units rated for zero clearance for both unit and duct.
Note: Horizontal units rated for zero clearance unit and 1" clearance for the first three feet of duct,
vertical units rated for zero clearance for both unit and duct.
Auxiliary Heat Electrical Data
Auxiliary Heat Electrical Data
Auxiliary Electric
Heat Model
Auxiliary Electric
Heat Model
AGM5A
HGM5A
AGM5A
AGM8A
HGM8A
AGM8A
AGM10A
HGM10A
AGM10A
AGM12A
HGM12A
AGM12A
AGL10A
HGL10A
AGL10A
AGL15A
HGL15A
AGL15A
AGL20A
HGL20A
AGL20A
All heaters rated single phase 208-230V 60Hz
Wire size based on 60°C (90*C)copper conductor
All heaters rated single phase 208-230V 60Hz
All models 12kW or larger feature internal circuit breakers
Wire size based on 60°C (90*C)copper conductor
All models 12kW or larger feature internal circuit breakers
TT
TT
36
HTV/HTD/HTH SERIES
HTV/HTH/HTD SERIES
Two Stage Geothermal Heat Pump Systems
Two Stage Geothermal Heat Pump Systems
HT
TT
024
036
048
060
070
026
038
049
064
072
230V
Heater Amps
Supply
Heater Amps
Circuit
Supply
230V
Circuit
230V
Single
20.0
Single
20.0
Single
31.7
Single
31.7
Single
40.0
Single
40.0
Single
47.5
Single
47.5
Dual - L1/L2
31.7
Dual - L3/L4
15.8
Dual - L1/L2
31.7
Dual - L3/L4
15.8
Single
40.0
Single
40.0
Single
60.0
Single
60.0
Dual - L1/L2
40.0
Dual - L3/L4
20.0
Dual - L1/L2
40.0
Dual - L3/L4
20.0
Single
80.0
Single
80.0
Dual - L1/L2
40.0
Dual - L3/L4
40.0
Dual - L1/L2
40.0
Dual - L3/L4
40.0
ClimateMaster : Smar t. Responsible. Comfor table.
Geothermal Heat Pump Systems
kW Rating
Btuh Rating
kW Rating
Btuh Rating
230V
208V
230V
208V
208V
230V
208V
4.8
3.6
16300
12300
4.8
3.6
16300
12300
7.6
5.7
25900
19400
7.6
5.7
25900
19400
9.6
7.2
32700
24600
9.6
7.2
32700
24600
11.4
8.6
38900
29200
11.4
8.6
38900
29200
9.6
7.2
32700
24600
9.6
7.2
32700
24600
14.4
10.8
49100
36900
14.4
10.8
49100
36900
19.2
14.4
65500
49200
19.2
14.4
65500
49200
Minimum
Circuit Amps
Minimum
Circuit Amps
208V
230V
208V
208V
230V
208V
17.3
25.0
21.6
17.3
25.0
21.6
27.5
39.6
34.4
27.5
39.6
34.4
34.7
50.0
43.4
34.7
50.0
43.4
41.2
59.4
51.5
41.2
59.4
51.5
27.5
39.6
34.4
13.7
19.8
17.1
27.5
39.6
34.4
13.7
19.8
17.1
34.7
50.0
43.4
34.7
50.0
43.4
52.0
75.0
65.0
52.0
75.0
65.0
34.7
50.0
43.4
17.3
25.0
21.6
34.7
50.0
43.4
17.3
25.0
21.6
69.3
100.0
86.6
69.3
100.0
86.6
34.7
50.0
43.4
34.7
50.0
43.4
34.7
50.0
43.4
34.7
50.0
43.4
Wire length based on one way measurement with 2% voltage drop
Part numbers with "H" included are for horizontal units only
Wire length based on one way measurement with 2% voltage drop
All Fuses UL Class K general purpose
Part numbers with "H" included are for horizontal units only
All Fuses UL Class K general purpose
23
26
30
Engineering Design Guide
Minimum
CFM
Minimum
Required
CFM
Required
500
500
650
650
650
650
750
750
1300
1300
1350
1350
1350
1350
Maximum Fuse
Supply Wire
Maximum Fuse
Supply Wire
Min
230V
208V
AWG
Min
230V
208V
AWG
25
25
10
25
25
10
40
35
8
40
35
8
50
45
6
50
45
6
60
60
6
60
60
6
40
35
8
20
20
12
40
35
8
20
20
12
50
45
6
50
45
6
80
70
6
80
70
6
50
45
6
25
25
10
50
45
6
25
25
10
100
90
2
100
90
2
50
45
6
50
45
6
50
45
6
50
45
6
Submittal Data
Max Ft
Max Ft
70
70
70
70
90
90
70
70
70
50
70
50
80
80
50
50
80
70
80
70
100
100
80
80
80
80

Advertisement