Vesta Ironworks 4 Installation And Operating Instructions Manual page 16

(4kw) woodburning stove

Advertisement

Flue connection
The stoves has both rear and top flue connection. The flue blanking
plate should be positioned over which ever outlet is not being used,
position the blanking plate over the outlet and use the access via the
opposite flue outlet to fix the clamp to the back of it, see
Figure
4.
Position the stove and seal the flue connections with fire cement or a
high temperature rope seal. Care should be taken not to allow fire ce-
ment to come into contact with the paintwork on either the stove or
the flue pipe. A rear flue can be secured to the stove by using 4 M5
nuts and bolts. The flue collar is predrilled to accept these.