Kenwood TK-3201 Service Manual page 22

Uhf fm transceiver
Hide thumbs Also See for TK-3201:
Table of Contents

Advertisement

TK-3201
Common Section
Item
Condition
1.Setting
1) BATT terminal votage:7.5V
2) SSG standard modulation
MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:5
voltage TX
PTT:ON
3.VCO lock
2) CH:1
voltage RX
Transmitter Section
Item
Condition
1.Frequency
1) CH:5-1
Adjust
PTT:ON
2.Power
TEST CH: 5-1
Adjust
BATT terminal voltage:7.5V
PTT:ON
3.VOX 1
TEST CH: 5-1
Writing
AG:1kHz/45mV
4.VOX 10
TEST CH:5-1
Writing
AG:1KHz/3.0mV
5.Max deviation TEST CH: 6-1
Adjust
AG:1kHz/150mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
6.DQT
TEST CH: 6-1
Balance Adjust LPF:3kHz
HPF:OFF
PTT:ON
7.QT Deviation TEST CH: 6-3
Adjust
QT:67.0Hz
LPF:3kHz
HPF:OFF
PTT:ON
8.DQT Deviation TEST CH: 6-6
Adjust
DQT:023
LPF:3kHz
HPF:OFF
PTT:ON
22
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
DVM
CV
Measurement
Test equipment
Terminal
Frequency counter ANT
Power meter
Ammeter
Power meter
ANT
Deviation meter
SP/MIC connector
Oscilloscope
AG
AF VTVM
ANT
Adjustment
Parts
Method
TC1
3.0 V
Check
Adjustment
Parts
Method
VR1
446.05625MHz
Programming
Software:KPG-90D
2.2kHz
(According to
the lager +,–)
Make the
demodulation
wave into
square waves
0.40kHz
0.35kHz
Specifications/
Remark
±0.1V
0.6V or more
Specifications/
Remark
±50Hz
0.6W ±0.05W
0.8A or less
±50Hz
±40Hz
±40Hz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents