Kenwood NXR-700 Service Manual page 48

Vhf digital base-repeater
Hide thumbs Also See for NXR-700:
Table of Contents

Advertisement

NXR-700
2. Replacing control Unit
2-1. Control Unit information
Original Control
Control Unit
Unit
(Service unit)
X53-4130-10
X53-4130-11
X53-4140-10
X53-4140-11
2-2. Supplied Accessories
Item (Including Part Number)
Control Unit (X53-413)
Control Unit (X53-414)
Kenwood ESN Label
NXDN ESN Label
Addendum (B59-2536-XX)
2-3. Printed Circuit Board DATA
The following data is written on the circuit board:
Data Type
Firmware
FPU Data
(PC programming mode)
Various Adjustment Data
(PC test mode)
Kenwood ESN
(X53-414 only)
NXDN ESN (X53-414 only)
48
TROUBLE SHOOTING
Difference between original
unit and Service Unit
Mounted chip at 0-11 location
for Service Unit.
Quantity
X53-413
X53-414
1
-
-
1
-
2
-
1
1
1
Description
NXR-700/800 Firmware
NXR-700 K type data.
General adjustment values for the
NXR-700/800.
Model Name: NXR-700/800S
Type: K
The same number as the Kenwood
ESN label is written.
The same number as the NXDN ESN
label is written.
Rear View
Kenwood ESN Label
Kenwood ESN Label
NXDN ESN Label (12 digits)
Note: For the X53-414, a UPC code and UPC barcode is not
printed on the Kenwood ESN Label. If necessary, cut the
label at the cut-off line and attach only the serial number.
2-4. After Changing the PCB
1. After changing the printed circuit board, write the up-
to-date Firmware following the instructions in the "RE-
ALIGNMENT 4. Firmware Programming Mode".
2. Using the KPG-109D, select your desired item (Model
Name and Frequency) from the Model > Product Informa-
tion menu, then use Program > Write to the repeater to
write the FPU data (PC Programming mode).
When writing to the repeater, a Warning Message, cor-
responding to the item selected, appears. Click [OK] to
continue writing the data.
3. Enter Program > Test mode, then adjust the various ad-
justment data (PC Test mode) as described in the "AD-
JUSTMENT".
4. For the X53-414, attach the new labels corresponding to
the new printed circuit board. (Refer to the images below
for label placement.)
5. If necessary, write the FPU data used by the customer
with the KPG-109D or KPG-110SM.
Note:
• When a new printed circuit board is used, the Kenwood
ESN changes, as does the Repeater Information display
of the KPG-109D, but this does not have any effect on
the operation of the transceiver.
• If changing to the original Kenwood ESN and NXDN ESN,
please contact our service center.
• Re-installing other parts from original unit to Service unit
is not required after changing to Service unit.
Cut-off Line
Kenwood ESN Label
Side View

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents