Page 1
Gas Water Heater Operation WARNING If not followed this Installation Manual exactly, a fire or explosion may result causing property damage, personal injury or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliance. - WHAT TO DO IF YOU SMELL GAS ...
Danger – Hot Water Temperature Setting ------- Personal Safety Equipment Protection and Personal Safety ----- Warranty Navien Warranty -------------------------------------- Navien America, Inc. Limited Warranty --------- Operating Instructions General Parts ------------------------------------------ Remote Controller ------------------------------------ LCD Display Icons ------------------------------------ Remote Controller On/Off -------------------------- Setting the Clock ------------------------------------- Hot Water Temp.
Safety Instructions Safety-related information and instructions have been provided in this manual and on the Navien combination water heater to warn any person(s) of potential hazards. Read and follow all safety information and instructions throughout this manual. It is very important to understand the safety instructions before installing, operating or servicing Navien combination water heaters.
DO NOT turn on the Combination Water Heater if cold water supply shut-off valve is closed. DO NOT use this Navien Combination Water Heater for other than its intended purpose as described in this manual. DO NOT attempt to repair or replace any part of your combination water heater unless it is specifically recommended in this manual.
Page 5
Combination water heater operation █ Safety Instructions Vapors from flammable Water heater has a main liquids will explode and burner flame: catch fire causing death or severe burns. 1. Which can come on at any Do not use or store flammable time ;...
Combination water heater operation █ Safety Instructions If you do not follow these instructions exactly, a fire or an explosion may result causing property damage, personal injury or loss of life. DO NOT OPERATE THE COMBINATION WATER HEATER. DO NOT OPERATE ANY FAUCET.
Combination water heater operation █ Safety Instructions This Navien Combination Water Heater is factory set at 120°F (49°C) for your safety and comfort. Increasing the set temperature increases the risk of accidental scalding. Consult the chart below before you decide to adjust the set temperature.
Combination water heater operation █ Equipment Protection and Personal Safety 1. Ignition Failure If the ignition fails, the gas supply is automatically cut off. An error code will appear as a flashing 2-digit code on the room thermostat. The error codes are discussed in the troubleshooting section of the operation manual.
Page 9
Combination water heater operation █ Equipment Protection and Personal Safety 9. Freeze Protection During the heating season, a sensor inside the combination water heater will automatically detect and initiate a safety heating cycle to prevent internal equipment damage from occurring freezing temperature exist. Note! -...
Applicable Warranty Period. At its option, Navien will replace the defective component part(s), in accordance with the terms of this Limited Warranty, if it fails in normal use and service during the Applicable Warranty Period.
One (1) year from the Effective Date. The payment and amount of any payment are subject to approval at Naiven‟s sole discretion. The Labor Allowance will be paid based on Navien‟s Schedule of Labor Allowances. TRANSFERABILITY This warranty is offered to the original and subsequent owners of the combination water heater but is limited to the original address registered with the warranty only.
Combination water heater operation █ General Parts CH Combination Water Heater Combustion Air Intake Exhaust Gas Front Cover Indicator Condensed Water Clean outlet Filter Water Inlet Condensed Water Water Inlet Filter Clean outlet Pump Drain Port Pump Drain Gas Connection Gas Connection Coke Strainer...
Combination water heater operation █ LCD Display Icons Timer display for 24 Room temperature hour clock Space heating Return Clock water temperature Space heating Supply Temperature temperature 24 Hour heating timer THERMOSTAT indicator controlled heating Hot water “ In use ” Lock Stand By Hot water pre-heating...
Combination water heater operation █ Remote Controller ON / OFF When the ON/OFF button is pressed, Press the ON/OFF button to turn the the LCD display switches to only a LCD on and off. clock display. In this status any heating mode &...
Combination water heater operation █ Hot Water Temperature Setting If the DHW button is pressed, „hot When the „hot water‟ icon flickers turn water‟ icon flickers and temperature the dial to set desire hot water of hot water (86~120℉) is displayed. temperature.
Combination water heater operation █ Pre-heating Setting Press and hold the “Stand By” and Please turn off the power of Remote “Program” buttons simultaneously for Controller pressing ON/OFF button. 3 seconds. When the “Clock” is flashing with the After setting the timer, press and hold cursor “■”use the center dial to “Stand By”...
Combination water heater operation █ Room Temperature Setting (Options) Tap “Heating” until “room temperature “Heating” “room when heating” icon appears. Leave alone temperature heating” icon is blinking and the display will automatically set. use the center dial to set the desired temperature between 50~100℉.
Combination water heater operation █ Return Temperature Control (Options) Tap “Heating” and when “Return Tap the “HEATING” button until the temperature heating” icon is blinking “Return temperature heating” icon use the center dial to set the desired appears. Leave alone and the display temperature between 90~140℉.
Combination water heater operation █ Supply temperature Control (Option) Tap “Heating” and when “Supply Tap “Heating” until “Supply temperature temperature heating” icon is blinking heating” icon appears. Leave alone use the center dial to set the desired and the display will automatically set. temperature between 105~185℉.
Combination water heater operation █ PROGRAM(24h timer) Setting for Space Heating When the “clock” is flashing with the Tap the “PROGRAM” button to set cursor, “■”use the center dial to move the “24 hour” timer. the cursor around. Tap the “HEATING” button to enable After setting the timer to the desired (solid) or disable (blank) the specified time frames, leave the remote alone...
Combination water heater operation █ STAND BY When the need for heat is not needed, the unit will set itself to operate in “stand by” mode. To Disable: Tap “STAND BY” and the To Enable: Tap “STAND BY” and the “stand by”...
Combination water heater operation █ Heat Capacity Control When the heating capacity is small, the desired heat capacity can be controlled by the use of the remote controller. With the remote Controller off, press and hold the “DHW” and “Stand By” Tap “ON/OFF”...
Combination water heater operation █ Capacity Control of The Whole Please follow this procedure if restricting heat capacity is needed Please turn off the power of Remote At this time, press the DHW and Heating Controller by pressing ON/OFF button. button simultaneously for 3 seconds.
Combination water heater operation █ Setting up the way of control of hot water Select which one will be used to control hot water temperature, supply water temperature or return water temperature. Please turn off the power of Remote If the program and heating button are Controller by pressing ON/OFF button.
Combination water heater operation █ Well pump setting User can select whether well pump will be used or not. Please turn off the power of Remote If the DHW button is pressed for 3 seconds, “IL P” is displayed inside the Controller by pressing ON/OFF button.
Combination water heater operation █ Supply water pressure setting Please follow the this procedure if setting up supply water pressure is needed If the heating button is pressed for 3 Please turn off the power of Remote seconds, “PS” is displayed inside the Controller by pressing ON/OFF button clock and desired supply water pressure is flickered where temperature was...
Combination water heater operation █ Function to set the number of initial Activating water heaters when cascade is used. Press and hold “DHW”, “Stand By” Please turn off the power of Remote and “Program” buttons simultaneously Controller pressing ON/OFF button. for 3 seconds.
Combination water heater operation █ Function to set pump activating water heaters when cascade is used. Press and hold “DHW”, “Stand By” Please turn off the power of Remote and “Heating” buttons simultaneously Controller pressing ON/OFF button. for 3 seconds. When the current setting state (C- Press “Program”...
Combination water heater operation █ Combination Water Heater: Heating (Mode) The space-heating water is controlled by the thermostat. Provided which that enables the user to either set the desired room temperature required or set the heating water temperature. In some cases this thermostat may not be suitable for multi-system applications (The installing contractor will make this determination and install suitable alternative controls).
█ Combination Water Heater: DHW (Mode) The domestic hot water (DHW) is controlled by the user. Because the Navien Combination Water Heater is a multi-purpose design, it can provide hot water on demand. The Navien Combination Water Heater only produces Hot Water only when you use it.
Combination water heater operation █ Cleaning the Combination Water Heater Regular Maintenance: Make sure the unit is OFF and the CAUTION electrical power supply been disconnected. The combination water heater may remain very hot for several minutes after it is turned off. To prevent burns, wait until the equipment has cooled down...
Combination water heater operation █ Draining the Combination Water Heater Draining the Combination Water Heater - Parts you need to know: Procedure to drain the combination water heater (figure below). You will need to prepare a bucket to collect some of the water to be drained. 1.
Combination water heater operation █ Auto feeder of the Combination Water Heater 1. Make sure the pump drain coke and the DHW cold water inlet filter have been inserted and that the drain coke inside the unit are closed. 2. Slowly open the water supply valve on the inlet to the unit. If there is no valve at the combination water heater, turn on the water supply at the water meter slowly.
Combination water heater operation █ Cleaning the Inlet Water Filter: Procedure to clean the DHW cold water inlet filter (figure below). You will need to prepare a bucket to collect some of the draining water. Turn off the power to the unit. Close the water supply valve on the inlet to the unit.
Combination water heater operation █ Cleaning the Strainer Strainer : Increases heating performance by filtering impurities from the system. When heating performance is decreased, clean the filter by removing clip, Removing filter washing out and re-inserting the filter. Replace the clip.
Combination water heater operation █ Cleaning the Intake Air Filter ※ If an intake air filter is blocked by dust or pollen, the combination water heater will not operate and „Error code 10‟ will be displayed. When this happen, please clean the combination water heater like the following.
The outdoor reset control operation (K-Factor) when enabled by connecting to the Navien CH unit can ensure that the system does not waste heat by exceeding current heat loss requirements, providing only the required fuel consumption, cerating loss pollution while saving you money.
Do NOT combination install this unit outdoors. To avoid any freezing issues, Navien strongly recommends the use of Direct Vent. Ensure the exhaust vent pipe AND the air intake pipe are both connected directly from the...
Asked Questions If an „Error Code‟ displays on the remote controller, follow the troubleshooting chart below before contacting your installer, service contractor or NAVIEN representative. Troubleshooting step #1 is to turn the unit OFF and then ON to reset the Navien combination water heater.
Page 41
Combination water heater operation █ Basic Troubleshooting and Frequently Asked Questions Problem Possible Cause(s) What to do Is the setting Use the center dial on the temperature remote controller to too low? raise the setting temperature. Is there power to the Make sure the power is System, or is the on, and plugged in to the...
3. Check ground wire. 4. Check power supply. E013 Abnormal Pump Activity 1. Check the pump. 2. Replace the pump. If any of the above solutions do not resolve the problem with the combination water heater, contact Navien‟s Technical department at 1-800-519-8794.
Page 43
E035 Abnormal activity of the gas pressure 1. Check gas line. sensor E036 Communication failure 1. Contact to Navien tech. dept. E037 Water leak Inside unit 1. Close DHW cold water main. 2. Replace leaking parts. E039 Abnormal the flow sensor.
Page 44
Combination water heater operation █ Memo...
Page 45
Combination water heater operation █ Memo ▒...