Location Of Controls; Self-Diagnostic Functions - Panasonic RX-D27E Manuals

Portable stereo cd system
Table of Contents

Advertisement

7. Location of Controls

8. Self-Diagnostic Functions

8.1. Setting of the Self-Diagnostic Mode
1. Switch the SELECTOR to CD and set to TAPE STOP state. (CD PLAY
2. Press the
/CLEAR for the first two seconds and followed by the FAST FORWARD
keys for another two seconds without releasing the
the Self-Diagnostic mode.
3. At the state of [ T ] display, operate as follows:
- Open the CD lid and close it right away.
- Start recording TAPE, and STOP it at once.
4. Press
/CLEAR key.
- Self diagnostic results, i.e. the memorized errors during actual operations and
the result of above-mentioned operation shall be displayed alternately.
- If there is no error, the aforementioned display [ T ], shall be kept.
- If the operation in the above mentioned in item 4 is made without executing the
procedure in item 3, [ H16 ] and [ F69 ] shall be displayed.
8.2. Display Location
/CLEAR key, it shall enter into
16
STOP)