Lubrication - PR SOLO 575 User Manual

Projector
Table of Contents

Advertisement

Any maintenance work should only be carried out by qualified technicians.
To ensure the continuous rotation of the rotating gobos and linear motion of the lens for focusing, it is
recommended that the bearings for the rotating gobos and the 3 shafts for the focusing lens holder be
lubricated periodically, preferably every two months. Use only high quality, high-temperature resistant
grease instead of any type of oil. When lubricating the bearings, a syringe with a fine needle is the
easiest way to introduce the grease to the bearings around each gobo.
To ensure the reliability of the projector it should be kept clean. It is recommended that the fans
should be cleaned every 15 days. The lens and dichroic colour filters should also be regularly cleaned
to maintain an optimum light output. Do NOT use any type of solvent on dichroic colour filters.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or
particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics. A soft cloth
and typical glass cleaning products should be used in cleaning. It is recommended to clean the
external optics at least once every 20 days and clean the internal optics at least once every 30 / 60
days.
Do not use any organic solvent, e.g. alcohol, to clean the reflector mirror, dichroic colour
filters or housing of the apparatus.
PROBLEM
The projector doesn't switch
on
The lamp comes on but the
projector doesn't respond to
the controller
The projector only functions
intermittently
Defective projection
The projected image
appears to have a halo
The beam appears dim

LUBRICATION

KEEPING THE PROJECTOR CLEAN
TROUBLESHOOTING
POSSIBLE CAUSE
-The power supply is not
present
-The lamp doesn't work
-Wrong DMX configuration
and/or start address
- Defective DMX cable
-The fan has failed
-The lens is broken
-Dust or grease on lenses
-Installation of the lamp is not
correct
-Dust or grease
contamination on the optics.
-Dust or grease contamination
on the optics.
-The lamp is at the end of its
life
ACTION
Check the fuse on the power
socket.
Replace the lamp.
Make sure that the projector is
correctly configured.
Replace or repair the DMX cable.
Make sure the fan is working and
not dirty.
Check the lenses are not broken.
Remove dust or grease from the
lenses.
Make sure the lamp is installed
correctly.
Carefully clean the optical group
lenses and the projector
components.
Check the optics is clean.
Replace with a new lamp of the
specified type and rating.