Level Range; Electrical Connection - U.s.a. Only - Whirlpool IEL730C Installation Instructions Manual

30" (76.0 cm) slide-in electric ranges
Hide thumbs Also See for IEL730C:
Table of Contents

Advertisement

Available languages

Available languages

Level Range

1. Place level on the oven bottom as indicated in one of the two
figures below depending on the size of the level. Check with
the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
Self-Clean Technology.

Electrical Connection - U.S.A. Only

If your home has a 3- or 4-wire receptacle, continue with "Install
Using a Power Supply Cord." If your home has a 3- or 4-wire
direct connection, go to "Install Using Direct Wire."
Install Using a Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Power supply cord strain relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and out
to remove cover from range.
A. Three mounting tabs
B. Lower access cover
C. Screws (2)
10
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Assemble a UL listed strain relief in the opening.
®
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
3-wire receptacle
(NEMA type 10-50R)
4-wire receptacle
(NEMA type 14-50R)
A
B
C
A
A. UL listed strain relief
And you will be
Go to Section:
connecting to:
A UL listed,
3-wire connection:
250-volt
Power supply cord
minimum,
40- or 50-amp,
range power
supply cord
A UL listed,
4-wire connection:
250-volt
Power supply cord
minimum,
40- or 50-amp,
range power
supply cord

Advertisement

Table of Contents
loading

Table of Contents