Adjustment Process Mode Menu - Sharp LC-32X20E Service Manual

Lcd colour television
Hide thumbs Also See for LC-32X20E:
Table of Contents

Advertisement

5. Adjustment process mode menu

The character string in brackets [ ] will appear as a page title in the adjustment process menu header.
Page
Line
1/33
[INFO]
1
MAIN Version
2
BOOT Version
3
Monitor Version
4
FRC Version
5
CPLD Version
6
EQ DATA CHECKSUM
7
LAMP ERROR
8
MONITOR ERR CAUSE
9
NORMALSTANDBY CAUSE
10
ERROR STANDBY CAUSE
2/33
[INIT]
1
INDUSTRY INIT
2
INDUSTRY INIT(-Hotel)
3
HOTEL MODE
4
Center Acutime
5
RESET
6
Backlight Acutime
7
RESET
8
LAMP ERROR RESET
9
ADJ PARAM SET
10
VIC XPOS
11
VIC YPOS
12
VIC SIGNAL TYPE
13
VIC READ
3/33
[TUNER ADJ]
1
RF AGC ADJ
2
TUNER ADJ
3
PAL+TUNER ADJ
4
RF AGC ADJ(CA-8CH)
5
TUNER ADJ(CA-8CH)
6
PAL+TUNER ADJ(CA-8CH)
7
RF AGC
8
TUNER DAC
9
RF AGC READ
4/33
[PAL MAIN]
1
PAL ADJ
2
SECAM ADJ
3
N358 ADJ
4
PAL CONTRAST
5
SECAM CONTRAST
6
N358 CONTRAST
5/33
[CEC TEST]
1
HDMI CEC TEST
2
INSPECT USB TERM
3
MONIDATA READ[TEMP/OPC]
4
CAUSE RESET
6/33
[COMP15KMAIN]
1
COMP15K ALL ADJ
2
COMP15K MAIN Y GAIN
3
COMP15K MAIN CB GAIN
4
COMP15K MAIN CR GAIN
5
COMP15K Y OFFSET
6
COMP15K CB OFFSET
7
COMP15K CR OFFSET
Item
Description
[1] 00H 00M
[2] 00H 00M
[3] 00H 00M
[4] 00H 00M
[5] 00H 00M
Enter
OFF
OFF
5H 0M
OFF
19H 35M
OFF
OFF
Enter
0
0
MAIN
OFF
Enter
Enter
Enter
Enter
Enter
Enter
16
150
OFF
Enter
Enter
Enter
130
137
120
Enter
Enter
OFF
Enter
Enter
194
215
212
66
512
513
LC-32X20E/S/RU, LC-37X20E/S/RU
Remarks (adjustment detail, etc.)
Main software version
BOOT Version.
Monitor software version
FRC Version
CPLD Version.
Audio data checksum.
Number of termination due to lamp error.
Last error standby cause.
Situation that became standby at the end.
(Excluding the error)
Error standby cause Total operating time before error.
Initialization to factory settings execution.
Initialization to factory settings execution.
(Hotel mode is excluded)
Hotel mode setting execution.
Main operating hours.
Main operating hours reset.
Backlight operating hours.
Backlight operating hours reset.
Lamp error reset.
ADJ PARAM SET
X-coordinate setting for VIC READ
Y-coordinate setting for VIC READ
Signal type setting for VIC READ
Picture level acquisition function
(Level appears in green on the upper right)
RF-AGC auto adjustment execution
TUNER auto adjustment execution
PAL TUNER auto adjustment execution
RF-AGC auto adjustment execution (CA-8CH)
TUNER auto adjustment execution (CA-8CH)
PAL TUNER auto adjustment execution (CA-8CH)
RF AGC adjustment
TUNER signal level adjustment
PAL adjustment
SECAM adjustment
N358 adjustment
PAL contrast adjustment
SECAM CONTRAST adjustment
N358 CONTRAST adjustment
CEC test
MONITOR Temperature/ OPC Acquisition tool.
Component 15K picture level adjustment
Y GAIN adjustment value
Cb GAIN adjustment value
Cr GAIN adjustment value
Y OFFSET adjustment value
Cb OFFSET adjustment value
Cr OFFSET adjustment value
3 – 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents