Ari Ratings - Lennox SPB036H4 User Manual

Outdoor unit, s-class split system r-410a two-stage compressor 60 hz, seer − up to 16.0 3 to 5 tons, cooling capacity − 34,600 to 58,500 btuh, heating capacity − 32,000 to 54,000 btuh
Hide thumbs Also See for SPB036H4:

Advertisement

ARI RATINGS

1
ARI Standard 210/240 Ratings
Capacity − Btuh
High
Low
Cooling Temp.
Cooling
Temp
Temp
Temp.
Heating SEER EER IV
Heating
SPB036H4
Air Handlers
34,600 33,000 20,000 14.70 11.20 8.00 6.70 3080 2980 2550 3.24 2.30
34,800 33,000 19,900 15.00 11.20 8.00 6.70 3065 2975 2540 3.26 2.30
34,800 33,600 20,400 13.80 10.80 7.95 6.90 3200 3045 2640 3.24 2.26
34,800 33,600 20,600 13.80 10.50 7.70 6.75 3285 3210 2740 3.06 2.20
35,200 33,000 19,900 15.50 11.50 8.00 7.00 3055 2900 2495 3.34 2.34
35,200 33,200 20,000 14.70 11.20 8.00 7.00 3105 2950 2550 3.30 2.30
35,400 33,400 20,200 14.50 11.20 8.00 6.70 3125 2950 2570 3.32 2.30
35,600 33,200 19,900 16.00 11.70 8.20 7.00 3045 2865 2480 3.40 2.34
35,600 33,000 19,700 15.70 11.70 8.20 7.00 3000 2835 2440 3.42 2.36
35,600 33,600 20,400 14.70 11.20 8.20 7.20 3110 2895 2470 3.40 2.42 CBX26UH−030 (Up−Flow / Horizontal)
36,000 33,600 20,400 14.50 11.50 8.20 7.20 3110 2865 2455 3.44 2.44 CBX26UH−036 (Up−Flow / Horizontal)
36,800 32,800 19,700 16.20 12.20 8.20 7.20 2970 2805 2385 3.42 2.42
Up−Flow Indoor Coils
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2995 2565 3.30 2.36
Up−Flow Indoor Coils + Furnaces
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3125 2915 2490 3.38 2.40 CX34−38A−6F
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3145 2930 2505 3.36 2.38 CX34−38B−6F
35,600 33,400 20,200 15.20 11.50 8.20 7.00 3100 2910 2475 3.36 2.38 CX34−38B−6F
35,800 33,200 20,000 15.70 11.70 8.20 7.20 3040 2830 2405 3.44 2.44 CX34−38B−6F
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3035 3075 2580 3.06 2.22 C33−44C
36,400 32,000 19,400 16.00 12.00 7.70 6.70 3000 3080 2560 3.04 2.22 CX34−43C−6F
36,400 32,200 19,500 16.00 11.70 7.70 6.70 3040 3095 2585 3.04 2.20 CX34−43B−6F
Down−Flow Indoor Coils
34,800 33,400 20,400 13.70 10.90 7.70 6.70 3190 3065 2610 3.20 2.28
35,800 34,000 20,600 14.20 11.20 8.20 7.00 3195 2950 2555 3.38 2.36
Down−Flow Indoor Coils + Furnaces
35,200 33,200 20,200 15.20 11.20 8.00 7.00 3100 2980 2520 3.26 2.34 CR33−48B−F
35,200 33,400 20,200 15.20 11.20 8.00 7.00 3140 2995 2550 3.26 2.32 CR33−48B−F
35,400 32,800 19,800 15.70 11.70 8.00 7.00 3000 2885 2425 3.34 2.40 CR33−48C−F
35,400 32,800 19,900 15.50 11.50 8.00 7.00 3015 2890 2435 3.32 2.40 CR33−48B−F
36,400 33,200 20,000 16.00 12.00 8.50 7.20 3005 2765 2370 3.52 2.48 CR33−50/60C−F
Horizontal Indoor Coils
34,800 33,600 20,400 13.70 10.95 7.70 6.70 3185 3045 2595 3.24 2.30
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2980 2555 3.32 2.36
Horizontal Indoor Coils + Furnaces
35,800 32,200 19,500 15.70 11.70 7.70 6.70 3035 3105 2590 3.04 2.20 CH33−42B−2F
36,200 32,000 19,400 16.00 12.00 7.70 6.70 3000 3085 2565 3.04 2.22 CH33−48C−2F
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3040 3075 2585 3.06 2.20 CH33−44/48B−2F
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings − 95_F outdoor air temperature and 80_F db/67_F wb entering indoor coil air.
High Temperature Heating Ratings − 47_F db/43_F wb outdoor air temperature and 70_F db entering indoor coil air.
Low Temperature Heating Ratings − 17_F db/15_F wb outdoor air temperature and 70_F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.
SPB − 3 to 5 Ton R−410A Heat Pump Outdoor Units / Page 10
Efficiency
Total Watts
HSPF
High
High Low High Low
Cool
Cool
Heat
V
COP
I d
Indoor Unit Model No.
Low
High
Low
Heat
Heat
Heat
Air Handlers
3
CBX32M−030 (Multi−Position)
3
CB30U−31 (Up−Flow)
3
CB29M−46 (Multi−Position)
3
CB29M−51 (Multi−Position)
4
CBX32MV−024/030 (Multi−Position)
3
CBX32M−036 (Multi−Position)
3
CB30U−41/46 (Up−Flow)
4,5
CBX32MV−036 (Multi−Position)
4
CBX27UH−036 (Up−Flow/Horizontal)
4
CBX27UH−042 (Up−Flow/Horizontal)
Up−Flow Coils
3
CX34−38A/B−6F
Up−Flow Coils + Furnaces
Down−Flow Coils
3
CR33−48B/C−F
3
CR33−50/60C−F
Down−Flow Coils + Furnaces
Horizontal Coils
3
CH23−51
3
CH23−65
Horizontal Coils + Furnaces
Expansion
Expansion
U it M d l N
Device
Factory TXV
2
49L24
Factory TXV
Factory TXV
Factory TXV
Factory TXV
2
49L24
Factory TXV
2
49L24
Factory TXV
Factory TXV
2
49L24
Factory TXV
4
G60UHV−36A−070
Factory TXV
4
G61MPV−36B−045
Factory TXV
4
G61MPV−36B−070
Factory TXV
4
G60UHV−36B−090
Factory TXV
4
2
G61MPV−36C−090
49L24
4
2
G61MPV−36C−090
49L24
4
2
G60UHV−36B−090
49L24
2
49L24
2
49L24
4
2
G61MPV−36B−070
49L24
4
2
G61MPV−36B−045
49L24
4
2
G61MPV−36C−090
49L24
4
2
G60DFV−36B−090
49L24
4
2
G61MPV−36C−090
49L24
2
49L24
2
49L24
4
2
G60UHV−36B−090
49L24
4
2
G61MPV−36C−090
49L24
4
2
G60UHV−36B−090
49L24
3 TON

Advertisement

loading

This manual is also suitable for:

Spb048h4Spb060h4