Power Supply CBA Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F2200, F2400) is blown , check to see that all components in the power
supply circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
WF9
D2102
CATHODE
WF10
D2405
ANODE
CAUTION ! :
For continued protection against risk of fire,
replace only with same type 2A, 250V fuse.
2A 250V
ATTENTION : Utiliser un fusible de rechange de même type de 2A, 250V.
1-10-22
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
WF13
D2351
ANODE
WF12
D2251
ANODE
WF11
D2750
ANODE
BL0700M01031