Kenwood TK-2312 Service Manual page 32

Vhf fm transceiver
Hide thumbs Also See for TK-2312:
Table of Contents

Advertisement

TK-2312/2317
Item
Condition
6. DQT Fine
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
7. QT Fine
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
8. DTMF Fine
1) TEST CH: 1
Deviation
LPF: 15kHz
[Wide]
HPF: OFF
PTT: ON
9. MSK Fine
1) TEST CH: 1
Deviation
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
Note: Regarding deviation alignment item, narrow value is calculated from wide alignment value.
Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Center, High
(Semiauto-
(3 points)
matic)
SSG otuput : –90dBm
(7.08µV)
SSG MOD: 3.0kHz
32
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
ANT
meter
Deviation
meter
Oscilloscope
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
DVM
Oscilloscope
Adjustment
Parts
Method
FPU
0.75kHz
±40Hz
0.75kHz
±40Hz
3.0kHz
±100Hz
3.0kHz
±100Hz
Adjustment
Parts
Method
FPU
Press [Start]
(Auto tuning)
Specifi cations / Remarks
Specifi cations / Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-2317

Table of Contents