FIGURE 12. GAS PIPING WITH
FLEXIBLE CONNECTOR.
FIGURE 13. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.

SEDIMENT TRAPS

A sediment trap shall be installed as close to the inlet of the water
heater as practical at the time of water heater installation. The
sediment trap shall be either a tee fi tting with a capped nipple in the
bottom outlet or other device recognized as an effective sediment
trap. If a tee fi tting is used, it shall be installed in conformance with
one of the methods of installation shown in Figures 12 and 13.
Contaminants in the gas lines may cause improper operation
of the gas control valve/thermostat and may result in fire or
explosion. Before attaching the gas line, be sure that all gas
pipe is clean on the inside. To trap any dirt or foreign material
in the gas supply line, a drip leg (sometimes called a sediment
trap) must be incorporated in the piping. The drip leg must be
readily accessible. Install in accordance with the "Gas Piping"
section. Refer to the current edition of the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.

FILLING THE WATER HEATER

Never use this water heater unless it is completely full of water. To prevent
damage to the tank, the tank must be fi lled with water. Water must fl ow
from the hot water faucet before turning "ON" gas to the water heater.
To fi ll the water heater with water:
1. Close the water heater drain valve by turning the handle to the right
(clockwise). The drain valve is on the lower front of the water heater.
2. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when
the water heater is in use.
3. To insure complete fi lling of the tank, allow air to exit by opening the
nearest hot water faucet. Allow water to run until a constant fl ow is
obtained. This will let air out of the water heater and the piping.
4. Check all water piping and connections for leaks. Repair as needed.

BLOWER ASSEMBLY INSTALLATION

SEQUENCE OF INSTALLATION
1. This power direct vent water heater comes with the blower
assembly installed.
2 After the unit is set in place, make sure the blower assembly is still
mounted securely, and make sure there is no damage to the blower.
3. Make sure there is no packing material in the discharge of the
blower or the intake, see Figure 15.
4. Make sure that the rubber tubing is still attached from the air
pressure switch to the port on the blower housing. Make sure
the rubber tubing is not folded anywhere between the pressure
switch and the blower housing.
5. Make sure the ON/OFF switch is in the OFF position and that
the wiring harness is connected from the blower control box
15
FIGURE 14.