Sanyo PLC-XU87 Service Manual page 42

Hide thumbs Also See for PLC-XU87:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
2 Connect
3 Position Horizontal
4 Position Vertical
5 Aspect Enable
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group 290 PanelType * Panel Type Check
0 GammaL/R-View
1 GammaL/R-Change
Group 500 Composite (NTSC) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 501 Composite (PAL) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 502 Composite (SECAM) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 510 SCART(480i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 511 SCART (575i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 520 YCbCr (480i)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 521 YCbCr (575i)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 522 YCbCr (480P)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 523 YCbCr (575P)
0 Total Dots
1 Disp Dots
2 H Back Porch
Function
Link Edit 1: Link
H-Position
V-Position
Aspect Enable (0: On, 1: Off)
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
Initial
0
100
100
0
0
1
5
1
1
0
0
10
668
28
34
458
658
34
22
536
652
28
22
536
662
142
48
456
458
162
64
534
890
696
150
48
58
920
704
170
62
542
858
684
138
46
460
862
680
148
-42-
Range
Note
0-1
68-132
68-100
0-1
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]
0 - 1
0: Executes Fine Phase, 1: Not Execute
0 - 3
0: Effective All Bit,
0 - 3
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable Lower 3 bit
0: Gamma for L-Turn
0-20
20: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is set to 0.
0-20
Sets R-Turn Gamma if the Value is set to 20.
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Read only
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
* Read only
0 ~ 4095
0 ~ 4095