Electrical Adjustments
Group/
Item Name
Item
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp C Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
Group 254 Fan Control Range Setting (Temp./Voltage)
0 n/a
1 n/a
2 n/a
3 n/a
4 n/a
5 n/a
6 n/a
7 n/a
8 n/a
9 n/a
10 Normal Fan Control Min Temp
11 Normal Fan Control Max Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Normal Fan4 Min
19 Normal Fan4 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
28 Eco Fan4 Min
29 Eco Fan4 Max
Group 255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 FNot used
3 Not used
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Not used
7 Not used
8 Cooling Time L1
9 Cooling Time L2
10 Temp Error Cooling Time
11 OnStart Cooling Start Threshold
12 After shutdown cooling
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
1 Lamp Vol Threshold
Function
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
Temp Senser Control Start/End Tem.p at
Normal
Fan voltage value at Normal (unit: 0.1V)
Temp Senser Control Start/End Tem.p at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x 30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read only)
Threshold to judge Lamp Voltage Down ( V×
10)
Initial
20
20
20
0
0
5
5
5
1
1
HiLand-
HiLand-
Normal
Ceiling
Normal
Ceiling
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
46
46
99
99
49
49
99
99
77
77
135
135
135
135
135
135
84
84
130
130
130
130
130
130
9999
9999
9999
9999
47
47
99
99
50
50
99
99
55
55
120
120
115
115
120
120
65
65
91
91
86
86
91
91
9999
9999
9999
9999
70
70
9999
9999
130
130
9999
9999
3
4
3
38
1
-
0
-40-
Range
Note
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
20-100
20-100
0-255
0-255
0-255
0-255
-
-
-
-
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
-
-
0-255
0-255
0-255
-
0-255
0-255
0-255
-
1-15
1-15
1-15
0-100
0-1
0-255
30-90