Receiver Section [Panel Tuning Mode except when Panel TEST Mode is specified.]
Item
Condition
4. RSSI
1) Adj item [LRSI]
(Low)
Adjust [∗∗∗]
Adjust
SSG OUT:
12dB SINAD level
2) Adj item
[L LRSI]
[C LRSI]
Adjust [∗∗∗]
5. Squelch
[Panel Test Mode]
(Preset)
1) CH-Sig:1-1
Check
SSG OUT:
12dB SINAD level
2) SSG OUT:OFF
6. RSSI
1) Adj item [HRSI]
(High)
Adjust [∗∗∗]
Adjust
SSG OUT:
-70dBm (70.7µV)
2) Adj item
[L HRSI]
[C HRSI]
Adjust [∗∗∗]
Adjustment points
TX-RX unit (X57-619X-XX)
component side view
ADJUSTMENT
Measurement
Test equipment
Unit
SSG
Panel
AF VTVM
Oscilloscope
[H LRSI]
[H HRSI]
Adjustment
Terminal
Unit
Parts
ANT
Panel
Encoder
knob
Universal
Connector
TK-285/(N)
Specifications/
Remark
Method
After input
signal from
SSG,press
[D] key.
That
numeric will
be stored
in memory.
Check
Squelch must
be opened.
Squelch must
be closed.
After input
signal from
SSG,press
[D] key.
That
numeric will
be stored
in memory.
31