Operation

Functions

Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
• Room temperature sensor (THERMISTOR)
Room temperature control
• Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
• Indoor fan is delayed for 5 seconds at the starting.
Time Delay Safety Control
• Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
• High, Med, Low and Auto
Operation indication Lamps (LED)
--- Lights up in operation
Healthy Dehumidification Mode
• Intermittent operation of fan at low speed
Sleep Mode Auto Control
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Auto Air Control by the unit electronic control
• The fan is switched to intermittent or irregular operation.
• The fan speed is automatically switched from high to low speed.
Chaos Swing
• The louver can be set at the desired position or swing up
and down automatically.
Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Defrost control(Heating)
• Both the indoor and outdoor fan stops
during defrosting.
• Hot start will be operated after
defrosting ends.
• The indoor fan stops until the
indoor pipe temperature will be
reached at 82°F(28°C).
- 37 -
Hot-start Control (Heating)
LGE Internal Use Only