Components Description - Kenwood KDC-MP332 Service Manual

Cd receiver
Hide thumbs Also See for KDC-MP332:
Table of Contents

Advertisement

ELECTRIC UNIT (X34-417x-xx)
Ref. No.
Application / Function
System µ-com
IC1
IC3
Power Supply
IC4
Power IC
IC6
Mute logic
IC7
RDS Decoder
IC8
Reset IC
IC9
MECHA+B
IC10
E-VOL.& Tuner
IC11
E2PROM
IC15
LED & VFD+B
Q51
Serge Det.
Q52
B.U. Det.
Q53
ACC Det.
Q54
BU5V SW
Q71
Control SW for SERVO+B
Q72,73
SERVO+B AVR
Q74
Control SW for IC3
Q91
Control SW for IC9
Q151
Panel 5V SW
Q152
FL+B SW
Q153
FL+B SW
Q156
EJECT ILLUMI SW
Q330
Mute driver for Q351, Q352
Q351
Mute SW for Lch PREOUT
Q352
Mute SW for Rch PREOUT
Q501
AM RF Amplifier
SWITCH UNIT (X16-349x-xx)
Ref. No.
Application / Function
IC2
Remote Control IC
Q4,5
SW5V
Q10
GREEN LED SW
Q12
GRID1 SW
Q13
GRID2 SW
Q14
GRID3 SW
Q15
RED LED SW
Q20
Key Scan Start SW

COMPONENTS DESCRIPTION

System controller.
DC5V x 1, 7.8V x 1, 8.0V x 1, 10.2V, P-CON, P-ANT output.
Signal amplifier.
Controls for mute action.
RDS decoder.
"L": detection voltage below 3.6V
Outputs 5V for CD mechanism.
E-VOL, Tuner, Stereo decoder.
Saves and loads for tuner adjustment data.
Outputs 11.25V for LED and VFD.
ON when the base goes "Hi".
ON when the base goes "Hi" during BU applied.
ON when the base goes "Hi" during ACC applied.
ON when the base goes "Lo".
ON when the base goes "Hi".
Output voltage is 7.5V.
ON when the base goes "Hi". Output voltage is 10.2V
ON when the base goes "Hi".
ON when the base goes "Lo".
ON when the base goes "Lo".
ON when the base goes "Hi".
ON when the base goes "Hi".
ON when the base goes "Lo".
Audio pre-output is muted when the base goes "Hi".
Audio pre-output is muted when the base goes "Hi".
Adjusts for gain.
The base of Q4 goes "L" when the base of Q5 is "H" and the power supply of IC2 is turned on.
GREEN LED is turned on when the base level of Q10 goes "H".
When the base of Q12 is "L", the current is supplied to G1.
When the base of Q13 is "L", the current is supplied to G2.
When the base of Q14 is "L", the current is supplied to G3.
RED LED is turned on when the base level of Q15 goes "H".
Key scan starts when the base of Q20 goes "H".
KDC-MP332/MP5033
KDC-W534/W534Y
Operation / Condition
Operation / Condition
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-w534Kdc-mp5033Kdc-w534y

Table of Contents