Float Setting; Fuel Level - Wisconsin VH4D Repair Manual

Hide thumbs Also See for VH4D:
Table of Contents

Advertisement

when startin{~
the engine.
The choke valve is of a =semi=automa-
tic s type, having a poppet valve incorporated
in its
design, which
is controlled
by a spring.
The poppet valve opens automatically
when the engine starts
and admits air to avoid over-choking
or
flooding of the engine.
The mixture required
for starting
is con-
siderably
richer
than that
needed to develop
power at normal
temperatures.
As the engine fires
and speed and suction
are in-
creased,
the mixture ratio
must be rapidly
reduced.
This change
is accomplished
through
adjustment
of the choke valve and the
automatic
opening of the poppet valve to admit more air when the
engine fires.
FLOAT SETTING, Fig.
5
If float
position
is not to the dimension shown, use a long nose
pliers
and bend lever close to float
body, to obtain correct
float
setting.
FUEL LEVEL
The liquid
level
in float
chamber is 17/32 to 19/32 inch below
top of float
bowl. This level
was established
with a #35 fuel
valve seat
at 1½ p.s.i,
and a sight
tube approximately
1/4 to
9/32 inch i.d.
MOVE GASKET AWAY FROM
L_
CONTACTS HEAD OF PiN
~
WITHOUT .PRESSURE.
1-5/32" + 1/32"
GASKET
37