ASSEMBLE THE HUMIDIFIER
Slide the mounting nut over the tube
(fig. 1)
Insert the tube assembly into the humidifier
valve. Secure by turning the nut clockwise
until finger tight, then additional 1/4 turn.
(fig. 2)
3 3
INSTALL THE HUMIDIFIER
Be sure to use a cold water
connection.
Mount the humidifier to the sheet
metal using the four #6 mounting
screws supplied. (Page 3)
The in-line water filter should be
mounted below or to one side of
the humidifier assembly in a vertical
position as shown. (Fig. 3)
Be sure the flow arrow on the filter is
pointing to the humidifier.
H
UMIDIFIER
assembly.
MOUNTING NUT
Fig. 1
Page 4
TUBE ASSY
Fig. 2
TOTALINE
R R
I
M
NTELLI
IST
C C
HUMIDIFIER
H1
H1
MODEL: P110-300
24 VAC 7.5 WATTS
H2
H2
US
C
LISTED
INTELLIMIST
4Z95
ON
Fig. 3