O Control; Configuring The Input Line; Assigning The Input Line To Receive A Hardware Trigger Signal - Basler SCOUT LIGHT User Manual

Gige vision cameras
Hide thumbs Also See for SCOUT LIGHT:
Table of Contents

Advertisement

AW00104701000
8 I/O Control
This section describes how to configure the camera's physical input line and the physical output
line. It also provides information about monitoring the state of the input and output line.
For more detailed information about the physical and electrical characteristics of the input and
output line, see Section 7.7 on
8.1

Configuring the Input Line

8.1.1
Assigning the Input Line to Receive a
Hardware Trigger Signal
You can assign the camera's input line to receive external hardware trigger (ExTrig) signals. The
incoming ExTrig signals can then be used to control image acquisition.
Section 9.4.5.2 on
page
how to configure the camera to react to a hardware trigger signal and how to assign the input line
to receive the hardware trigger signal.
The default line assignments depend on the image acquisition control mode:
Standard mode:
By default, physical input line 1 is assigned to receive an ExTrig signal to serve
as the frame start trigger.
Legacy mode:
By default, physical input line 1 is assigned to receive the ExTrig signal to
serve as the acquisition start trigger.
Basler scout light GigE
page
64.
97, Section 9.5.3.4 on
page 107
and Section 9.6.3.4 on
I/O Control
page 119
explain
71