5
7. GENERAL INFORMATION
7.1 DIAGNOSIS
7.1.1 TEST MODE
Version indication
[Purpose]
The versions for various microcomputers and DSP firmware are displayed.
[How to enter/exit]
During Standby mode, simultaneously press and hold the STANDBY/ON and SOUND RETRIEVER keys for 5
seconds to enter this mode. This mode is automatically exited when the indications of all versions have finished.
[Basic operations]
FL Display
POWER OFF
Mx.xxx : Main microcomputer
Fx.xxx : Display microcomputer
PPP.xx : DSP firmware
USB xxxx.xx.xx
Normal display
[Notes]
1. If the version indication becomes "**," a failure in communications between the corresponding microcomputers or
a failure in the corresponding microcomputers is likely.
2. In this submode, the user settings will not be cleared.
3. If the USB firmware version indication becomes "**," return the unit to Normal mode, switch Function to USB, then
reenter Test mode and check the USB firmware version. If the indication becomes "**" again, communication
between the main microcomputer and the USB firmware is in failure.
5
6
Description of Version
Indications
: USB firmware
6
7
Duration
Devices that can be considered generally
(sec.)
normal, with the corresponding indications
5
Main microcomputer and display microcomputer
5
DSP firmware (in Main microcomputer)
USB firmware
5
: Flash ROM (IC762) near the USB IC (IC701)
VSX-1016V-K
7
8
A
B
C
D
E
F
193
8