A-1
TECHNICAL SPECIFICATION INVERTER ARC™ 120
Input Voltages 60 Hz.
120Vac ± 15%
Duty Cycle
20%
Output Current Range
10-90 Amps
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
120/60
Height
7.5 in.
190.5 mm
OPERATING TEMPERATURE RANGE
-10°C to +40°C

INSTALLATION

INPUT - SINGLE PHASE ONLY
RATED OUTPUT
Output Amps
Output Volts
70A (Stick)
OUTPUT
Maximum Open Circuit Voltage
72 Volts Max.
TYPE SJT OR HARD USAGE INPUT
CORD
3 Conductor, 14 AWG
PHYSICAL DIMENSIONS
Width
5.0 in.
127.0 mm
TEMPERATURE RANGES
INVERTER ARC™ 120
Rated Input Current
20 Amps @ Rated Output
22.8 Vdc
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
Length
10.9 in.
276.9 mm
STORAGE TEMPERATURE RANGE
-25°C to +55°C
A-1
Input Circuit
120 Vac
Type of Output
DC
20
Weight
Approx. 14.0 lbs.
6.4 kgs.