  • Page 1 Re:connect M 203 EIB/ KNX Bridge Dominating Entertainment. Revox of Switzerland...
  • Page 2: Revox Eib Protocol

    This Operating manual describes the layout and the setting options on the M203 EIB-Bridge pages. The description does not include the Revox EIB Protocol that the EIB programmer must adhere to, so that the M203 EIB-Bridge can recognise the incoming EIB Group addresses and convert them into functions for the Revox Multiroom System.
  • Page 3: Table Of Contents

    Connection plan Connections M51 Link IN M51 Link OUT Serial interface RS 232 IR-Link Connection example EIB-Part Connection example Revox MR-Part Setup key #1 Slot Selection #2 EIB Address #2 EIB Debugger Released EIB products Overview Revox Multiroom System Technical Data...
  • Page 4: M203 Eib Bridge

    The M203 EIB-Bridge establishes The M203 EIB-Bridge is only the bridge between on the one designed to handle communi- side the Revox Multiroom System cation with an EIB data interface and on the other side, the EIB and cannot receive any other Domestic facility management protocols.
  • Page 5: Connections

    M203 EIB/ KNX Re:connect Connection: Connection M203 with M51 M203 with external interfaces Socket: M51 LINK IN Socket: M51 LINK OUT The M203 interface is The M51 LINK OUT can be connected to the M51 LINK IN used to connect additional socket on the back of the M51 external interfaces to the M203 with the telephone cable...
  • Page 6: Serial Interface Rs 232

    If the customer requires it, the face, the M203 EIB-Bridge can keypad units shown for communicate with a serial data controlling the Revox Multiroom interface from an EIB system. System, are programmed through an EIB tool, e.g. ETS3. Only Type FT 1.2 EIB data...
  • Page 7: Ir-Link

    11. the 3-pin, screw-fixable Phoenix plug connection. An M218 wall-mounted remote control, with integrated IR Revox recommends the use of receiver, can be connected a 2-core screened cable instead of the M204 IR receiver. (microphone cable), where the screening is used as ground.
  • Page 8: Connection Example Eib-Part

    M203 EIB/ KNX Re:connect Connection example – EIB part...
  • Page 9: Connection Example Revox Mr-Part

    Connection example – Revox MR part The EIB wall-mounted keypad units are installed in the required (additional) rooms, which make up the Revox Multiroom System. Each Additional room amplifier can be addressed over the M203 EIB-Bridge. Additionally, the Additional room amplifier can be integrated into a...
  • Page 10: Setup Key

    M203 EIB/ KNX Re:connect Setup key Slot Selection Using the Setup key, you can If a second M203 (M200) is call the M203 menu, which connected to the M51 Link appears in the M51 display. output, a different address must be assigned through the slot selection so that both M203s don’t occupy the same slot address.
  • Page 11 The definition of the middle (Y) The installer can assign different and lower (Z) group addresses is main group addresses, in the handled by the Revox protocol. range from 0 to 15, when pro- An individual group address YZ gramming the EIB bus coupler...
  • Page 12: Eib Address

    Receiver If you want to have The number of received EIB Multiroom control through a protocols. Revox remote control as well as through the EIB keypad Transmit units, an “invisible” IR control The number of EIB protocols sent can be achieved using the to the EIB data interface.
  • Page 13: Released Eib Products

    Combi-interface with integrated BCU2: Merten Part no.: 6816 Because other EIB products from other companies are also certified, it is theoretically possible to work with them. However, Revox gives no guarantee if you choose to work with one of such products.
  • Page 14: Overview Revox Multiroom System

    Revox Multiroom System overview The overview shows the maximum The following Operating manuals contain a detailed number of (Additional) rooms in a Revox Multiroom System, if description of the Revox Multiroom System. no M217 Wall-mounted display • Multiroom Module (MK 1 – 3) is used and if the room control is done through the EIB system.
  • Page 15: Technical Data

    M203 EIB/ KNX Re:connect Technical data IR-LINK: Positive voltage 10-20V (DC) IR signal Ground (GND) Dimensions: 113 x 25 x 50 mm (WxHxD) Weight: 150 g Power consumption: 35 mA (without IR receiver) Max. cable length: 100 m (M203- M51) Max.
  • Page 16 Re:connect M203 EIB/ KNX GERMANY Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 0, Fax +49 7721 8704 29 info@revox.de, www.revox.de SCHWEIZ Revox Schweiz AG, Wehntalerstrasse 190, CH-8105 Regensdorf Telefon +41 44 871 66 11, Fax +41 44 871 66 19 info@revox.ch, www.revox.ch...