Install Warning Labels; Partial Opening Feature - PowerLift CS60EVO Installation And Operating Instructions Manual

Sectional garage door opener
Table of Contents

Advertisement

25

INSTALL WARNING LABELS

For Service Call
Installation Date
114A3361
Three warning labels are provided with this opener: attach as indicated in the fig 1 to a clean and suitable surface.
1. Risk of entrapment: (English version) - place close to a fixed Wall Control(1).
2. EMERGENCY Release/Service label: - place on the Manual Release cord (2).
3. WARNING Child Entrapment: (triangle label) - place on a low inside panel of the door (3).
26
PARTIAL OPENING FEATURE (PET)
This is an adjustable, second stop position suitable for
ventilation, pedestrian or pet access, programmed to the Remote
Control or Wireless Wall button.
To Activate this feature:
1.Start with the door fully CLOSED. Drive the opener UP and
stop at the position required for PET access.
2.Enter PET activation mode by pressing the PROG and UP
buttons together for 3 seconds (figure 1). Release when the
Courtesy light flashes once.
3.Press the Remote Control button that you have allocated for
this feature (figure 4). Do not use the button already allocated
for normal operation. The Courtesy light will flash once when
the code is accepted.
TEST: Press the Remote Control once, and door will close, press
again, and door will return to the preset position.
If the door is above the preset position, when the button
is pressed, it will fully close.
To Deactivate this feature:
1.Start with the door fully CLOSED.
2.Enter PET Activation mode by pressing the PROG and UP
buttons together for 3 seconds (figure 1). The Courtesy light
will flash twice, indicating the deactivation has occurred.
NOTE: Erasing all remote control codes, as in the Wireless
programming section, will also delete this feature.
A
B B
2
3
For Service Call
Installation Date
114A3361
figure 1
figure 2
figure 3
figure 4
15
1
RISK OF ENTRAPMENT
Repeat Safety Reverse Test monthly. Door
must reverse on contact with a 40mm obstacle
placed on the floor. Make necessary adjustments.
AUTOMATIC DRIVE:
Keep away from the area of the door since it may
operate unexpectedly.
EMERGENCY RELEASE:
To release, pull down firmly on the red handle.
Indicator LED
Indicator LED
Indicator LED
or
132A2900