Advertisement

Operation & Maintenance
ST. CROIX FEATURES .......................................................................................3
INSTALLATION.................................................................................................. 4
PREVENTING CHIMNEY PROBLEMS.......................................................... 4
SATISFACTORY PERFORMANCE................................................................. 4
APPROVED FUELS .............................................................................................4
,
OPERATING INSTRUCTIONS......................................................................... 6
Control Board Features.............................................................................7
Pre-Lighting Instructions..........................................................................8
Lighting Your Stove ................................................................................. 8
Shutting the Stove off ............................................................................... 9
Diagnostic Features....................................................................................9
Safety Features ..................................................................................... 9-10
Combustion Air Damper .................................................................. 10-11
Thermostat Control ................................................................................ 12
MAINTAINING THE STOVE ..........................................................................12
Clinker Removal ......................................................................................12
Daily Maintenance ........................................................................... 13-16
Periodic Maintenance ...................................................................... 16-18
Yearly Maintenance ............................................................................... 19
SAFE OPERATION ........................................................................................... 20
TROUBLESHOOTING AND FAQ ............................................................ 21-25
PARTS LAYOUT .......................................................................................... 26-27
WARRANTY....................................................................................................... 28
NOTES ..................................................................................................................29
Auburn
Manual

Table of Contents

608
1
Auburn Operations & Maintenance Manual

Advertisement

Table of Contents
loading

Summary of Contents for St. Croix Auburn

  • Page 1: Table Of Contents

    MAINTAINING THE STOVE ................12 Clinker Removal ..................12 Daily Maintenance ................13-16 Periodic Maintenance ..............16-18 Yearly Maintenance ................19 SAFE OPERATION ................... 20 TROUBLESHOOTING AND FAQ ............21-25 PARTS LAYOUT ..................26-27 WARRANTY....................... 28 NOTES ........................29 Auburn Operations & Maintenance Manual...
  • Page 2 St. Croix corn stove. 1. Have your new St. Croix corn stove installed by trained, qualified personnel. 2. Use only clean, dry quality corn for optimum performance in your St. Croix corn stove. 3. Faithfully adhere to the maintenance program described in this manual. Thank you for selecting a St.
  • Page 3: St. Croix Features

    Control Board With Diagnostic Features Slide Track To hide Controls Behind stove Coal Rake Thermostatic Control Option Available Slide-out Patent Pending Bottom Rod Burn System Large Ash Pan Area With Quick Release Latches Figure 1 Auburn Operations & Maintenance Manual...
  • Page 4: Installation

    Fly ash. The stove is not warranted against damage caused by Clean the exhaust system if needed. Use of poor quality corn, incorrect operation, poor an appropriately sized chimney brush or the maintenance or incorrect installation. Auburn Operations & Maintenance Manual...
  • Page 5 Distiller’s Grain pellets Pellets When burning Distiller’s Grain pellets or any St. Croix Corn stoves come equipped with other fuels mixed with Distiller Grain Pellets, a burn pot installed that has removable the side shields must be removed. Failure to side shields.
  • Page 6: Operating Instructions

    ON PAGES 21 – 25 BEFORE OPERATING 3. Carefully clean all marks off the gold plated THE STOVE. parts before the first fire is lighted. Use a soft cloth and a “Windex” type cleaner. Caution: Auburn Operations & Maintenance Manual...
  • Page 7: Control Board Features

    Heat Level one can be up when needed. This is particularly helpful in adjusted in the following ways: priming the Auger Tube when it is empty. Auburn Operations & Maintenance Manual...
  • Page 8: Pre-Lighting Instructions

    Make sure there is corn in the hopper. CAUTION: NEVER ADD FIRE STARTER TO A HOT STOVE. Add one cup of Pellets to the burn pot (not more and not less). Do not try to start your stove Auburn Operations & Maintenance Manual...
  • Page 9: Shutting The Stove Off

    110 degrees F are not sensed during the #2 and #3 LED lights will flash start up or if the temperature drops below simultaneously. (See Figure 3 on Page 7 110 degrees during normal operation. and point 6 on page 22) Auburn Operations & Maintenance Manual...
  • Page 10: Combustion Air Damper

    Stove shuts down. This is sufficient for corn burns in the St. Croix corn burning system. The the Daily Maintenance burn pot should be “BALANCED”. What this means is the corn that is being augered into the burn The St.
  • Page 11 Check the burn pot to see if it is adjust the stove to the unique circumstances of your balanced. Most likely the stove will be home. burning fine at this point, because the damper was preset at the factory. Auburn Operations & Maintenance Manual...
  • Page 12: Thermostat Control

    Once a clinker has formed in the burn pot, the goes from a #1 setting to a #5 setting will almost problem is how to get rid of it. The St. Croix Burn always have problems making that transition. The system is designed to be able to remove the clinker burn pot will overload and the fire will go out.
  • Page 13: Daily Maintenance

    Exchange Tubes and cleaning the Glass. A break down of this process consists of these steps: Note the position of the Coal Rake Rod and the Slide-out Pot Bottom Rod during normal operation!! Normal Operation Figure 6 Auburn Operations & Maintenance Manual...
  • Page 14 Quickly push the bottom in again. To pull out the slide bottom use the Rod Handle tool shown in figure 9 on page 16 (see point 2 at the top of page 16). Auburn Operations & Maintenance Manual...
  • Page 15 Use of a glass cleaner ONLY permitted when the Stove is cold. CAUTION: Do not slam the door. Do not operate the Stove with a broken or cracked glass. Replace only with heat resistant ceramic glass supplied by the manufacturer. Auburn Operations & Maintenance Manual...
  • Page 16: Periodic Maintenance

    Clean burn grate holes whenever needed. Remove the Burnpot and use a small metal object (Nail, Drill Bit, etc) to clean out plugged holes. (See Figure 9 & 10) Figure 9 Burnpot & Slide-out Bottom Removal Auburn Operations & Maintenance Manual...
  • Page 17 Figure 10 shows how the baffle is removed from the Stove. Clean the baffle on a regular basis. Frequency of cleaning depends on amount of fuel being burnt and the quality of the corn. Failure to clean the Baffle can cause the stove to become plugged with Fly Ash. Auburn Operations & Maintenance Manual...
  • Page 18 Exhaust system and Ash Traps at least once every two months during the heating season. 6. Gaskets. Periodically inspect the condition of the rope gasket around the door, window and ash door. Replace as needed. Auburn Operations & Maintenance Manual...
  • Page 19: Yearly Maintenance

    Call dealer for this service. Annual oiling of the motors is not needed. (See Figure 12) 5. The Convection Blower should be removed and cleaned with compressed air annually. Annual oiling of the motors is not needed. (See Figure 12) Auburn Operations & Maintenance Manual...
  • Page 20: Safe Operation

    CAUTION: The Electrical Components of the stove are not Owner Serviceable. Call your dealer for proper diagnosis of electrical problems and service to those components. See Installations Manual for a copy of the Wiring Schematic. Auburn Operations & Maintenance Manual...
  • Page 21: Troubleshooting And Faq

    If the fire is out, re-light the stove. If the fire is still burning make sure all doors are securely latched and hold down the On/Off button (approximately 5 seconds) until stove starts up again. This will restart the stove in the start-up program. Auburn Operations & Maintenance Manual...
  • Page 22 The stove did not establish a vacuum and shut down. With the fuel in the pot burning, the smoke finds the path of least resistance and leaks out into the house. (See Installations Manual. Minimum vertical height needed to establish some natural draft and prevent smoke spillage) Auburn Operations & Maintenance Manual...
  • Page 23 Check the fuse on the back of the control board. Replace with a 125 Volt, 5 Amp fuse. Part Number 80P20057-R Why is my glass dirty? Normal operation of your St. Croix corn stove will produce a white build-up on the glass that wipes off with a dry paper towel. However extended burning on the low setting only will produce a light tan color.
  • Page 24 LED lights will flash once. Remember: Any of the above mentioned adjustments to the #1 setting on the control board will be lost if the unit gets unplugged or if there is a Power Failure. Auburn Operations & Maintenance Manual...
  • Page 25 Operations Manual and perform all the maintenance issues covered in the Daily and Periodic Maintenance section of the Manual. If the stove still does not operate correctly call your Dealer for Assistance. Auburn Operations & Maintenance Manual...
  • Page 26: Parts Layout

    80P30045-R T-STAT WIRE TERMINAL 80P52630-R WIRING TERMINAL BLOCK 80P20278-R AUGER MOTOR 80P20245-R AUGER GASKET 80P52232-R QUICK DISCONNECT GASKET 80P20168-R COMBUSTION FAN GASKET 80P53650-R EXHAUST ADAPTER WELDMENT 80P52887-R PIPE CONNECTOR ASSEMBLY 80P52957-R AUGER MOUNT BRACKET ASSEMBLY Auburn Operations & Maintenance Manual...
  • Page 27 5/8” FLAT GLASS GASKET 80P60083-R GLASS RETAINER CLIP 08P20026-R 5/8” DOOR ROPE GASKET 80P20025-R ASH PAN DOOR GASKET 80P20004-R POWER CORD 80P52693-R WIRING HARNESS 80P52946-R ASH PAN 80P53666-R AUGER SHAFT WELDMENT 80P20057-R 250 VOLT 5 AMP FUSE Auburn Operations & Maintenance Manual...
  • Page 28: Warranty

    This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. Auburn Operations & Maintenance Manual...
  • Page 29: Notes

    Draft Trim: Circle one (See point 4 on page 7) Default Draft Low Draft High Draft Feed Trim: Circle one (See point 5 on page 7) Default #1 #1-High #1-Low Serial Number: Date of Purchase: Dealer Information: Auburn Operations & Maintenance Manual...
  • Page 30 Even Temp, Inc. P.O. Box 127 Waco, NE 68460 EMAIL: service@eventempinc.com WEB ADDRESS: www.stcroixheat.com Auburn Operations & Maintenance Manual...

Table of Contents