SchraderAir SA315240H346 Operating And Maintenance Manual

SchraderAir SA315240H346 Operating And Maintenance Manual

Compressor two stage 15 hp pump

Advertisement

Quick Links

Compressor Operating and
Maintenance Manual
TWO STAGE 15 HP PUMP
SA315240H346
MODEL: _________________________
SERIAL #_________________________

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA315240H346 and is the answer not in the manual?

Questions and answers

Summary of Contents for SchraderAir SA315240H346

  • Page 1 Compressor Operating and Maintenance Manual TWO STAGE 15 HP PUMP SA315240H346 MODEL: _________________________ SERIAL #_________________________...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS When using air compressors and compressed air 9. Drain tank daily to prevent rust formation in the accessories, basic safety rules and precautions should tank. always be followed including the following: 10. Never reset pressure switch or safety valves. 11.
  • Page 3: Unpacking Instructions

    This compressor was shipped without oil. Before operating, fill crankcase with oil to level on oil sight gauge. Do not over fill. Oil recommended: Premium Grade SchraderAir 826020 - 30WT Non-Detergent. Change oil every three (3) months or 500 hours. After initial start up change oil after first two weeks of operation. If oil turns milky replace oil and move unit to less humid conditions.
  • Page 4: Wiring Diagram

    WIRING DIAGRAM Installation Should Be Made By a Competent Electrician C1 - Blue & Orange C2 - C3 - Black & Red Jumper Phase Motor L2, L3 indicates supply line terminals. T1, T2, T3 indicates load.
  • Page 5 Every 90 days or 1,000 operating hours, Disassemble and wash element in detergent whichever comes first, change crankcase oil. solution. Do not oil. Oil recommended: Premium Grade SchraderAir • Check V-belts for tightness. Belt tension should 826020 - 30WT Non-Detergent. Change oil more...
  • Page 6: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Compressor will not operate. 1. No electrical power. 1. Turn on power. 2. Pressure switch not making contact 2. See pressure switch adjustment. 2. Excessive noise in operation 1. Loose pulley, flywheel, belt, beltguard, 1. Tighten. cooler, clamps or accessories.
  • Page 7 TROUBLESHOOTING (continued) PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 9. Air blowing our of inlet 1. Broken first stage inlet valve. 1. Replace valve assembly. 10. Insufficient pressure at point of use. 1. Leaks or restriction. 1. Check for leaks, restriction, or piping.
  • Page 8 823015 Two-Stage Compressor Pump...
  • Page 9 823015TX - PUMP PARTS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 430001 Crankcase GS43 431030-1 HP Wrist Pin - Piston GS43 430002 Cap-Rear GS43 431031 Snap Ring - Internal 430003 Crankshaft GS43 45-1 431031-1 Snap Ring - Internal Piston Ring Set GS43 430004 Balance GS43 431032...
  • Page 10 82-P7575 - Check Valve...
  • Page 11 DAFENG LIDA COMPRESSED AIR SYSTEMS CO.,LTD 823015 Two-Stage (SINO-USA) Compressor Pump DAFENG LIDA COMPRESSED AIR SYSTEMS CO.,LTD 823015 Technical Data Motor 823015 Technical Data Dimensions ACFM 43.1 inch 15.59 Air Delivered /min 1.22 inch 8.98 Pressure Motor Dimensions inch 6.85 Cylinders ACFM 43.1...
  • Page 12 AIR CONSUMPTION CHART SCFM SCFM Air file Spray gun 4.0* Production 90-100 16.0* Air filter cleaner 70-100 3.6* Touchup 90-100 8.0* Undercoating 90-100 19.0* Air motors Tire bead breaker 1 HP 125-150 12.0* 2 HP 13.0 3 HP 19.0 Tire changer 125-150 Air polisher Tire hammer...
  • Page 13: Warranty Statement

    Schrader International Inc. Warranty Statement For (1) one year from the date of purchase, Schrader Inter- To locate the closest Authorized Service Center for service national Inc. will replace or repair for the original purchaser assistance, resolution of a service problem or for product free of charge, any part or parts found upon examination information and operation, call or write to: by manufacturer/any Authorized Service Center to be...
  • Page 14 CUSTOMER SERVICE • SALES 1-800-327-1335 TECHNICAL SERVICE • PARTS 1-800-345-0578 Schrader International, Inc. P.O. Box 668 • 205 Frazier Road Altavista, Virginia 24517 823015 Manual 011112...