3.4.3
Remove the plug from the bottom right hand side of the tank (fig.3) and
attach a suitable length hose It should have an inner diameter of 5/8"
and secure with a hose clip.
3.4.4
Thread the hose through the hole in the bottom right hand side of the
base of the unit, insert the tank ensuring that the hose is not kinked.
3.4.5
Continue to use the dehumidifier as normal.
4.
MAINTENANCE
4.1
Cleaning Air Filter
The dehumidifying capacity is lowered when the air cleaning filter
becomes clogged.
4.1.1
Open the front door of the unit.
4.1.2
Lift up the filter element from the bottom as shown in fig.4 and lift
out of the holder.
4.1.3
To dislodge the dust from the filter, use a vacuum cleaner or tap it
lightly.
4.1.4
If the filter is very dirty, wash it carefully in water with a neutral
detergent, then rinse well with clean water and leave until dry.
4.1.5
To refit the air filter locate the top of the element into the locating
bracket at the top of the door and then locate the lower section into
the lower bracket.
4.1.6
Close the door of the dehumidifier.
4.2
Storage
4.2.1
Unplug the unit, bundle the power cord, and hang the bundled cord
at the back of the unit.
4.2.2
Remove the water collection tank and empty the water out of it.
Remove the tank cover and wash the inside of the tank with clean
water. The tank may be scratched if it is scrubbed strongly with a
brush. Do not remove the float lever from the tank. Wipe off the
water on the outside of the tank with a cloth. Refit the tank cover
onto the tank and replace the tank in position.
4.2.3
Clean the air filter (see 4.1).
4.2.4
When the unit is to be stored for a long time, wipe the dehumidifier
over with a dry soft cloth. To remove dirt, wipe over with a very
slightly dampened cloth (never use a wet cloth for cleaning the
controls). To avoid deformation or cracking, do not use benzine,
thinner or liquid cleaners.
4.2.5
When storing, place in a safe, dry, childproof location. Stand the unit
upright and avoid exposure to direct sunlight.
5 .
TROUBLESHOOTING
Problem
Cause
Will not run
Switch is not "ON"
Unit is not plugged in
Fuse blown
Water tank full
Dehumidifier inefficient
Filter blocked
Inlet or outlet vents restricted
Doors or windows open
Refrigerant leak
Water leaking from unit
Dehumidifier is not level
Reservoir float not shutting down unit
6 .
DECLARATION OF CONFORMITY
Declaration of Conformity
standards and directives
Industrial Dehumidifier
Models: SDH30, SDH50
2006/95/EC Low Voltage Directive
2004/108/EC EMC Directive
2002/95/EC RoHS Directive
2002/96/EEC WEEE Directive
93/68/EEC CE Marking Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
We, the sole importer into the UK, declare that the product listed below is in conformity with the following
The construction file for this product is held by the Manufacturer and may be inspected on
request by contacting Jack Sealey Ltd.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Drain plug and continuous
draining hose connection
fig.3
fig.4
Remedy
Switch "ON"
Insert plug
Replace fuse
Empty water tank
Clean filter
Remove restriction
Close openings
Contact Sealey dealer
Adjust position of dehumidifier
Contact Sealey dealer
Signed by Steve Buckle
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 757500
01284 703534
Error Codes
Problem
E1
Humidity sensor faulty
E2
Refrigerant sensor faulty