Datalogic Rhino 10 Installation Manual

Hide thumbs Also See for Rhino 10:

Advertisement

Quick Links

TM
Rhino
10
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Rhino 10

  • Page 1 Rhino Installation Manual...
  • Page 2 U.S.A. http://www.mobile.datalogic.com © 2011 Datalogic Mobile, Inc. • All rights reserved. • Protected to the fullest extent under U.S. and international laws. • Copying or altering of this document is prohibited without express written consent from Datalogic Mobile, Inc. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries including the U.S.A.
  • Page 3: Table Of Contents

    Contents Safety Information ...............................1 Service and Support ..............................1 Web Support................................1 Related Documents ..............................1 Telephone Support.............................1 Introduction .................................2 Packing List.................................2 Rhino™ 10 Unit ..............................2 Mount (optional)..............................2 Keyboard (optional) ..............................2 Keyboard Mount (optional) .............................2 Connecting the Computer ............................3 USB 1 and USB 2...............................3 COM 1 &...
  • Page 4 < page intentionally left blank>...
  • Page 5: Safety Information

    4. Choose the Product documentation you want to download. See User Manual for Safety and Regulatory statements information. Telephone Support For telephone support, select Contact Us on the Datalogic Mobile web page and select the country where you are lo- cated.
  • Page 6: Introduction

    Installation Manual Rhino™ 10 Introduction Before you begin to install and connect your new computer, take a few minutes to verify that everything you ordered is included in your shipment and that you have the necessary tools to complete the installation. Packing List Rhino™...
  • Page 7: Connecting The Computer

    Rhino™ 10 Installation Manual Connecting the Computer The Rhino™ 10 connectors are on the bottom of the unit. In addition to the power connector the computer has two communication ports (COM1 and COM2) and two USB ports. It may also include an Ethernet interface port if you or- dered this option.
  • Page 8: Ethernet (Optional)

    Installation Manual Rhino™ 10 Table 1 – COM1 Pin-Out Description Name Description Carrier Detect Receive Data Transmit Data Data Terminal Ready ------ System Ground Data Set Ready Request to Send Clear to Send SPWR Power (None, +5V, +12V @ 1A max) Table 2 –...
  • Page 9: Mounting The Rhino™ 10

    Rhino™ 10 Installation Manual Figure 3 – Power Connector Table 3 – Power Connector Pin-Out Description Pin # Function Cable Color Chassis Ground Brown Not connected + Power, 10-60V Blue Ground Black Mounting the Rhino™ 10 Caution: The touch panel consists of a plastic film covering glass. Use care when handling the Rhino™ 10 during mounting to avoid damage to the touch panel.
  • Page 10: Assemble The Mounting Arm

    Installation Manual Rhino™ 10 Figure 4 – Base without Keyboard Mount Figure 5 – Base with Keyboard Mount Assemble the Mounting Arm The mounting arm may come unassembled. Put the parts together as shown in Figure 6 and tighten the nut 2-3 turns. Then, place the arm on the ball of the base with the spring side of the arm farthest away from to the unit.
  • Page 11: Attach The Rail Base To The Vehicle

    Attach the Rail Base to the Vehicle There are two different bases available from Datalogic, the Ram 4” Rail Base (P/N 94ACC0035) and the Ram Mount with Round Base (P/N 94ACC0034). This section describes the use of the standard rail mount base.
  • Page 12: Mount The Computer To The Vehicle

    Installation Manual Rhino™ 10 Mount the Computer to the Vehicle Hold the computer by the junction of the Ram mount arm and the base on the back of the unit. Lift the assembly to the base on the vehicle. Open the arm until the end slides over the ball on that base. Tighten the wing nut firmly. Once the computer is attached, it can adjusted by holding the bottom of the computer, loosening the wing nut on the arm by one turn moving the Rhino™...
  • Page 13 Rhino™ 10 Installation Manual 3. Align the keyboard with the offset holes men- tioned in the previous step and attach the key- board to the mounting plate using the four re- maining 8-32 screws and lock washers. 4. Plug the USB cable into the top USB port on the Rhino™...
  • Page 14: Attaching The Rhino™ 10 To Power

    Installation Manual Rhino™ 10 Attaching the Rhino™ 1 0 to Power or the Rhino™ 10 to operate, you must provide power from the vehicle DC power supply (12V – 60V) or from an AC/DC power supply. Positive power should go to a non-switched conn ection, so the unit retains power even when the vehicle is off.
  • Page 15: Fixed Mount Power Supply

    Rhino™ 10 Installation Manual T able 4 – Power Wiring Descriptions Item Number Description Vehicle Power Source Fuse Holder Positive Supply Negative Supply Chassis Ground Blue wire Black wire Brown wire The fuse holder comes with a 2A fuse (Littlefuse 0312002.HXP) installed for use with 24/36/48 V vehicles.
  • Page 16: Installing An External Antenna

    Installation Manual Rhino™ 10 Installing an External Antenna Option 1 – Rabbit Ears If you purchased external dipole antennas, simply screw them onto the two connectors on the top of the unit. For a more secure connection, use a drop of Loctite medium on the connector threads before attaching the antennas. Figure 11 –...
  • Page 17: Connecting A Scanner

    The voltage selection jumpers are located under the top right cover. This operation requires an ESD protected workstation! Failure to prevent ESD damage may void the warranty. If in doubt, have an authorized Datalogic Partner perform this installation for you.
  • Page 18: Increasing Memory Storage

    You must remove the top cover using a 1/16” Allen driver to access the SD card slot. This operation requires an ESD protected workstation! Failure to prevent ESD damage may void the warranty. If in doubt, have an authorized Datalogic Partner perform this installation for you.
  • Page 19: Cleaning The Screen

    Products containing less than 4% Isopropyl Alcohol are acceptable if all excess cleaner is removed. Contacting Product Support If you cannot find the answer to your problem in this manual, you can visit the Datalogic Customer Service site at www.mobile.datalogic.com to review technical information or to request technical support.
  • Page 20 World wide Sales Network available from: www.mobile.datalogic.com/contacts Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 Lippo di Calderara di Reno Bologna - Italy Telephone: (+39) 051-3147011 Fax: (+39) 051-3147561...

Table of Contents