Technical data
Heating
1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
Potentiometer
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Water valves
Inlet valve
Voltage
Frequency
Resistance
Regenerating valve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reedcontact
flow meter
Whirlpool Europe
Customer Service
220/230
V
1.87/2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
85
˚C
0.0
kΩ
0.5
kΩ
1.0
kΩ
1.4
kΩ
1.8
kΩ
2.3
kΩ
2.6
kΩ
220/240
V
50/60
Hz
3.76
kΩ
220/240
V
50/60
Hz
3.13
kΩ
220/240
V
50/60
Hz
1.5
kΩ
ADP 931/2 WH
8542 931 01310
NTC
15 ˚C
20 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Regeneration
Volume
Position 0
after wash cycles
water hardness
Position 1
after wash cycles
water hardness
Position 2
after wash cycles
water hardness
Position 3
after wash cycles
water hardness
Position 4
after wash cycles
water hardness
Position 5
after wash cycles
water hardness
Position 6
after wash cycles
water hardness
Salt consumption
for regeneration
Number of cycles
with 2 kg salt
23.06.1998 / Page 3
Doc. No: 4812 718 13521
75
kΩ
62
kΩ
43
kΩ
28
kΩ
19
kΩ
13
kΩ
9
kΩ
6
kΩ
5
kΩ
3
300
cm
10
0-5
˚dh
0-0.9
mmol/l
0-9
˚Fh
8
6-10
˚dh
1-1.8
mmol/l
10-18
˚Fh
6
11-15
˚dh
1.9-2.7
mmol/l
19-27
˚Fh
4
16-21
˚dh
2.8-3.7
mmol/l
28.37
˚Fh
3
22-28
˚dh
3.8-5.0
mmol/l
38-50
˚Fh
2
29-35
˚dh
5.1-6.3
mmol/l
51-63
˚Fh
1
36-60
˚dh
6.4-10.7
mmol/l
64-107
˚Fh
77
g
26

Hide quick links: