For installations that must conform to the requirements of the UK specific standard LPS1277 make sure the installation conforms to the requirements set out in Chiron’s installation guide “IRIS Touch Range Dialler Installation Guide for LPS 1277 Compliant Applications”. IRIS Touch 400 Range Dialler Installation Manual V1.4...
IRIS Touch 420 - Ethernet IRIS Touch 440 - Ethernet & GPRS The IRIS Touch dialler should be located within the alarm panel tamper protected enclosure and powered from the alarm panel battery backed power supply. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Configuration and diagnostics over Ethernet Secure polling (monitoring) over GPRS Secure alarm transmission over GPRS Configuration and diagnostics over GPRS IRIS Touch 400 Range Dialler Installation Manual V1.4...
Page 10
Serial port for connection to alarm panel for fast upload/download Call confirmation ‘polling’ over PSTN Alarm transmission over PSTN Pin inputs for alarm transmission over PSTN IRIS Touch 400 Range Dialler Installation Manual V1.4...
The GPRS Access Point Name (APN) of the SIM card provider. Some networks also require a User Name and Password which can also be obtained from the SIM card provider. (Ethernet & GPRS only.) IRIS Touch 400 Range Dialler Installation Manual V1.4...
If the panel is required to make outgoing calls over IP for upload/download or remote configuration, then where the telephone number for this would normally be entered, put in the digit ‘8’ followed by the destination IP address in 12 digit format, as above. IRIS Touch 400 Range Dialler Installation Manual V1.4...
5. Fit the SIM card (GSM / Ethernet & GPRS only) Fit the SIM card. Power must not be applied to the PCB while the SIM card is being fitted or removed or it may be damaged. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Page 14
Note: This resistor enables the IRIS dialler to detect cable faults and/or tampers and must be fitted at the alarm panel end of the cable to function correctly. IRIS Touch 400 Range Dialler Installation Manual V1.4...
(GSM / Ethernet & GPRS only.) Once the installation is completed successfully the message Status - System OK is displayed on the Welcome screen and the LED Indicator on the PCB is on steady. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Fast Format alarm messages over IP to the monitoring centre. The messages for each PIN can be configured via the Settings Menu on the touch screen display. See Appendix A for more details. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Installation Wizard for all inputs in use, or for each input individually in the Settings menu . The monitoring centre must also enable the monitoring of this facility on the dialler within the IRIS receiving system. IRIS Touch 400 Range Dialler Installation Manual V1.4...
The relay contacts are normally open and closed when activated. Wire to these contacts as required and define how they are to be used using the configuration options on the Settings Menu. See Appendix A for more details. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Touch the display and the instructions will indicated by the LED on the guide you through identification of the PCB flashing. problem. Go to the Installers menu and select Test to use the integrated test function. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Activation of relay outputs by incoming SMS messages. Language Selects language. Installer Password Sets a password to the Installer menus, if required. Contrast Sets display contrast. Restore Clears tamper alarm if tamper switches have been triggered. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Page 21
Sets all settings back to factory defaults. Indicates when current software (note – not the physical Build Information hardware) was built. Reflash Allows dialler software to be updated to latest version from Chiron’s Reflash Server. IRIS Touch 400 Range Dialler Installation Manual V1.4...
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will also be additional transient peak current of up to 250mA required as GSM and GPRS transmissions (e.g. for network registration and calls) are made. Weights Dialler unit 300g Fully packaged 500g IRIS Touch 400 Range Dialler Installation Manual...
Page 24
For conformance to the requirements of EN60950, the dialler must be powered from a Limited Power Source as defined in EN60950. The output of the power supply should be fused at 3.0A (slow blow). IRIS Touch 400 Range Dialler Installation Manual V1.4...