MANEUVER MODES
The device can work in three different modes:
TWO CHANNELS:
This mode activates the relay assigned to each user upon receiving a call. It is useful
in installations with two devices.
X and Z are configured timings for the signals in each relay.
OPEN/CLOSE:
This mode uses RELAY 2 to open the gate upon receiving a call and RELAY 1 to close
the gate upon receiving the next call. It is possible to set an automatic close timer to
close the gate automatically.
X is the configured timing for the opening signal in RELAY 2, Y is the automatic close
timer, and Z is the configured timing for the closing signal in RELAY 1 If Y is set to 0,
the gate will only close after receiving a call.

AUTOMATIC CYCLE:

This mode uses the specified relay to open and, after a set amount of time, will use
the same relay to close. It is possible to close earlier after receiving a call during its
set period of time.
X is the configured timing for the opening signal, Y is the set amount of time before
Z, which is the configured timing for the closing signal. If Y is set to 0, the gate will
only close upon receiving a call.