Web server

Web server
In order to configure the WiCOS AP access point and with it the complete WiCOS
conference system, you have to call up the web server of the access point. For this,
you require a computer with network connection (RJ 45). For more information on
EN
the web server, refer to the detailed instruction manual.
Use the supplied network cable (Cat5) to connect the network socket (RJ 45)
of the access point to your computer.
Make sure that your computer is set to the same address range as the access
point (IP range: 192.168.0.xxx, subnet mask: 255.255.255.0).
In the address box of the browser (e.g. Internet Explorer or Firefox), type the
IP address of the access point "192.168.0.10".
The web server appears and prompts for a password.
Factory default settings of the access point's web server
IP address
Subnet mask
Password

Accessories and spare parts

WiCOS AP specifications
Frequency response
Frequency ranges
Signal-to-noise ratio
Supply voltage
Power consumption
Operating temperature
Dimensions
Weight
Color
"192.168.0.10"
"255.255.255.0"
"123"
Accessories and spare parts for the WiCOS conference system can be found
on our website at www.sennheiser.com.
150–15000 Hz
2.4 GHz; 5.1–5.8 GHz
> 70 dB(A)
24 V
6 W
41°F to 113°F
approx. 10.24 x 9.05 x 1.5 in.
approx. 2 lbs. 11.03 oz.
RAL 7035