Calibration And Setup - iKonavs ECM User Manual

Table of Contents

Advertisement

Press the Set button ( top left ). Red led will illuminate.
Select all channels on unit to be calibrated using buttons 1 to 8.
Play audio source at Max SPL approx. Audio must be present for a period of
one minute ( minimum ).
Press the set button ( top left ). Red led will now flash on and off.
Then stop audio.
Introduce 20KHz at low level and observe the yellow LED's above channel
number.
LOAD
SHORT
OK
The OK LED and the Short LED should be illuminated to show the 20KHz signal
to LOW.
Increase the 20KHz level until the Short LED goes out.
When only the OK led is lit on channels 1 to 8 press the SET button again and
calibration is complete.
The OK LED should remain lit.
To test a circuit simply remove 20KHz signal and observe LED's on that channel.
A LOAD fault should be shown illuminated.
Return the 20KHz signal and the OK LED should be shown illuminated.