Agri-Alert 800EZe Alarm System User’s Manual ZONES Alarm System in Standby Burglary Armed Online (phone) ZONE LIGHTS LEGEND Green = zone activated Red = zone in alarm Amber = zone bypassed Off = zone deactivated Main Menu AM / PM A B C D E F Alarm...
Page 2
The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information con- tained in it is however subject to change without notice due to further developments. AA800EZe rev.03...
Make sure the cover Date installed: can be opened easily (to open the enclosure, pull the latch and lift the cover). If outdoor connections are used, mount the enclosure as close as possible to the entry point of the outdoor wiring. AA800EZe rev.03...
(WM-3000). In case of power for normal battery life spans. Device failure, the battery back-up provides 12VDC to this line. Battery Connector Before making the connections, pass the wires through an hermetic cable holders at the bottom of the enclosure. Battery Pack AA800EZe rev.03...
(be sure to line up the ground con- 10ft (3 m) 10ft nector of the card with the quick connect (3 m) 10ft (3m) pin of the bottom board). The phone plug-in metal rod card is optional. Bedrock AA800EZe rev.03...
Speaker: The speaker delivers the system identification and alarm messages. Integrated Microphone: The microphone is used to record ID messages and gives an on-site listening input. AA800EZe rev.03...
(if the zone in alarm uses the dialout function). The siren stops ringing when the alarm is acknowledged. If the alarm is not acknowl- edged at the end of the dialout sequence, the Agri-Alert automatically acknowledges it and stops the siren. AA800EZe rev.03...
Page 9
(*). Status of the chosen zone: - Activated; - Bypassed; - Deactivated; - Not installed; - Alarm (if the zone is in alarm); - Temperature (if this is a T° zone). [System returns to the main menu] AA800EZe rev.03...
This user level gives a read/write access to all password protection or select “No” to dis- functions of the system, including the event able it. buffer menu. Users — Use the numeric keypad to specify the password of each users. AA800EZe rev.03...
Wed Oct 14 2008 ranges from 1 to 15 minutes and is set to Date Format — Select the proper date format 11:59:00 AM 5 minutes by default. (Year/ Month/ Day). Back Press Enter to start editing the time and date. AA800EZe rev.03...
“Yes” if an outside temperature sensor is con- message to be delivered through the speaker. nected to the Agri-Alert. If an alarm situation occurs while the voice is mute, the system sends out an alarm sound instead of a vocal message. AA800EZe rev.03...
Use the numeric keypad to select the Normal State (NO / NC) — Select the normal desired zone number. state of the zone contact: Normally open or normally closed contact. AA800EZe rev.03...
90.0°F Critical T° Set. 100.0°F Rec.Time (h:m:s) 0:00:30 Select “Rel.1” or “Rel.2” to assign the 1 Zone 2 Back relay to the selected zone; select “None” if no relay is assigned to that zone. Set the following parameters: AA800EZe rev.03...
Agri-Alert then plays the new message over Back Modify the speaker. Original ID Message — Press the pound key Press the zone number on the keypad “#” to retrieve the original ID message. to change the zone status. Select “Yes” to activate it. AA800EZe rev.03...
(this process takes about 10 seconds). Once the calibration is over, the Agri-Alert starts monitoring the level of sound and triggers an alarm if it gets higher than the sample sound for a period of time exceeding the recognition time. AA800EZe rev.03...
“Record” is displayed. It then plays the recorded sound through the speaker. 7. Dialout Sequence — The system launches the dialout sequence. 800 EZe VX.X.XXXX Jan 1 20XX Base Mx Vx AA800EZe rev.03...
If a phone number is busy, the Agri-Alert puts dialout sequence from the start: it at the bottom of the list and calls all busy numbers at the end of the sequence (the number of time busy numbers are called is defined by the user). AA800EZe rev.03...
Agri-Alert restarts the Agri-Alert to call all stored phone numbers the dialout sequence when an alarm condition when there is an alarm. that has been acknowledged is still valid. The recall time is set to 30 minutes by default. AA800EZe rev.03...
“AAAA” is an alarm code generated by the Agri-Alert. If more than 1 alarm is ac- tive, alarm codes are dis- played one after the other. In the example below, alarm code 3000 identifies a test call. AA800EZe rev.03...
By default this function is disabled. Rings to Answer — If the Agri-Alert does not share the phone line, set the number of rings at which it answers a call. By default, the number of rings is set to 8. AA800EZe rev.03...
Time of Day — Set the time of day at which the test call is made. Day of Week — If test calls are made on a weekly basis, select on what day of the week they must be sent. AA800EZe rev.03...
Outdoor card disconnected / 30 seconds Temperature alarm defect No alarm High T° alarm No dial tone 3 trials limit Outside temperature High T° alarm offset (no alarm) limit Offset Outside temperature Low T° Low T° alarm alarm limit limit Time AA800EZe rev.03...
T° Comp. Status — Select “Yes” to enable the outdoor compensation function or select “No” to disable it. Make sure the “Outdoor” card is plugged in the controller before enabling the compensation function. This card is sold separately. AA800EZe rev.03...
Status — This is the current status of the Recognition Time — Determine during how selected zone. Here is a list of all possible much time the alarm condition must be status: maintained before it constitutes a valid alarm situation. AA800EZe rev.03...
• Zone Inputs Wired Phone is off Relay 2 is on hook (The sys- (activated) • Phone / Siren / Relays connected tem uses the phone line) • System Programmed • System Function Tested • End User Instructed AA800EZe rev.03...
(“AA800~1.PKG” for instance). • Main Menu The AA800EZe can read and write on stan- This way, the Agri-Alert will never erases an • System Auxiliaries dard memory cards (SD/MMC cards). These existing file.
Make sure the entry line is plugged in the right connected phone jack of the phone plug-in card. TYPE: ........AA800EZe line" icon is Make sure the plug-in card is properly inserted in Operating Temperature: ..32 to 104°F (0 to 40°C) displayed.
2. Unplug the wall transform- er and the battery and then replug them. The Agri-Alert will reboot. 3. Try uploading the file once again. If the problem persists, con- tact your dealer. AA800EZe rev.03...
Initialize 13 Contrast 7 Testing the sequence 17 View/Modify 25 Location 7 Display screen Sensor wiring 5 Testing the LCD screen 17 see LCD screen Status LED 7 LEDs Vocal identification 15 LED meaning 7 Testing the LEDs 17 AA800EZe rev.03...
Page 31
Status report call 8 Getting reports over the phone System test 17 Test call 22 Alarm reports 8 Troubleshooting guide 28 Automatic test call 22 Version 17 Call-in settings 21 Vocal identification 16 Message repetition 19 Wiring 5 AA800EZe rev.03...
Page 32
View/Modify 25 Units of measurement 11 Vocal identification 15 Test System test 17 Test call 22 Time Time format (AM/PM - 24h) 11 Transformer 28 Troubleshooting guide 28 Units of measurement 11 Upgrade 27 User password see Password AA800EZe rev.03...