Sanyo PLC-XE50 Service Manual page 24

Sanyo plc-xe50 multimedia projector service manual
Hide thumbs Also See for PLC-XE50:
Table of Contents

Advertisement

Mechanical disassemblies
8
Lamp Cover Switch removal.
1. Remove the 2 screws-A(T3x8), remove the Spacer sheet, remove the Holder-SW and remove the
Thermal Switch (SW902)
2. Remove the screw-B(T3x8) and remove the Lamp cover switch (SW901).
A
Holder -SW
Thermal SW(SW902)
Spacer sheet
A
B
Lamp cover SW(SW901)
- 24 -

Advertisement

Table of Contents
loading

Table of Contents