Installation
Preparation
PREPARE ELECTRICAL WIRING
A
WARNING!
FORPERSONALSAFET~
Remove house fuse or open circuit breaker
before beginning
installation.
Do not use an extension
cord or adapter
plug with this appliance.
GROUNDING
INSTRUCTIONS--Power
Cord
Models
This appliance
must be grounded.
In
the
event of a malfunction
or
breakdown,
grounding
will reduce
the
risk of
electric shock
by
providing
a path ofleast
resistance
for electric current.
This appliance
is
equipped
with a cord
having an equipment-grounding
conductor
and a grounding
plug. The plug must be plugged into an appropriate
outlet that is installed
in an accordance
with all
local codes and ordinances.
A
WARNING!
Improper
connection of
the
equipment-grounding
conductor can result in a risk of electric shock .Check with a qualified
electrician
or service representative
if you are in doubt wether the appliance is properly
grounded.
Do you
modify
the plug
provided with the appliance;
Hit
will
not fit the
outlet,
have a proper outlet installed by a qualified
electrician.
GROUNDING
INSTRUCTIONS--Cable
Direct
This appliance
must be connected
to a grounded
metal,
permanent
wiring system ,or an equipment-grounding
conductor
must be run with the circuit
conductors
and connected
to
the
equipment-grounding
terminal
or lead on
appliance.
ELECTRICAL REQUIREMENT
This dishwasher
is
designed
for operation
on an
adequately
wired individual
120VAC, 60HZ,
and connected
to an
individual,
properly
grounded
branch
circuit,
protected
by
a 15 or 20 amp circuit
breaker
or time-delay
fuse.
lf the electric
supply
provided
does
not meet the above
specifications,
it
is
recommended
that a licensed
electrician
install an approved
outlet.
Your dishwasher
circuit should not be used for
any
other appliance
while the dishwasher
is in operation
as the
dishwasher
requires
the full
capacity
ofthe circuit.
lf the wall socket you plug the dishwasher's
power cord into is controlled
by a
switch,
turn off the switch before
installation.
1 The
power-supply
socket
for the
appliance
shall be
installed
in a cabinet or on a wall adjacent
to the
undercounter
space in which the appliance
is
to be
installed.
2
There
shall be an opening through the partition
between
the compartments
specified in 1 that
is
.
large enough for the attachment
plug to pass through.
The longest dimension of the opening shall not
be
more than 38mm.
3 The edges of the opening specified in 2 shall, ifthe
partition
is wood,
be
smooth and rounded,
or, if the
partition
is metal,
be covered with an edge protector
provided
for this purpose
by the
manufacturer;
and
Figure 8
4 Care shall
be
exercised,
when the appliance
is
installed
or
removed,
to
reduce
the likelihood
of
damage to the
power-supply
cord.
ELECTRICAL
CONNECTION
Electrical
connection
is on the right front of
dishwasher.
For cable
direct
connections
the cable must be routed as shown. Cable must extend a minimum
of24"
from
the rear
wall.
For power cord
connections,
install
a
3-prong
grounding
type
receptacle
in
the
sink
cabinet rear wall,
6"
min.
Or
16"
max. From the opening,
6"
to
16"
above
the floor.
3

Advertisement