Sharp JH-1600E Service Manual page 16

Solar power conditioner
Hide thumbs Also See for JH-1600E:
Table of Contents

Advertisement

List of Parameters for Operating Condition
Function explanation:
1.
Utility over voltage (Vac): Setting utility over voltage trigger value.
2.
Utility under voltage (Vac): Setting utility under voltage trigger value.
3.
Voltage abnormal trip time (sec): Setting trip time when over and under voltage
protection is triggered.
4.
Utility over frequency (Hz): Setting utility over frequency trigger value.
5.
Utility under frequency (Hz): Setting utility under frequency trigger value.
6.
Freq. abnormal trip time (sec): Setting trip time when over and under frequency
protection is triggered.
7.
Recover timer: Setting solar power conditioner recovery time when error occurrence.
8.
RJ-45 ID: Setting RJ-45 ID number.
9.
Operation frequency: Setting utility frequency.
Table2. Setting value and parameter (The shadow value is default setting.)
Item
1
Utility over voltage (Vac)
2
Utility under voltage (Vac)
3
Voltage abnormal trip time (sec)
4
Utility over frequency (Hz)
5
Utility under frequency (Hz)
6
Freq. abnormal trip time (sec)
7
8
9
Function
Recover timer
RJ-45 ID
Operation frequency
Parameters
250
255
205
210
1
1.4
52
53
46
47
1
1.4
10
60
5
6
50
60
15
260
215
1.8
54
48
1.8
150
300
......
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents