The 2WAY-UNIVKF is compatible with virtually any control panel either through bus compatible operation or universal mode
operation. When used on a panel on which it is bus-compatible, full functionality is realized, including lighting, appliance and X10
control. When used in the Universal Mode, functionality is dependent on the feature set of the control panel, such as a keyswitch
arm zone for arm / disarm capability, an armed output to provide an Armed indication, a steady bell output for an alarm indication
and a pulsing bell output for a fire alarm indication.
This manual is divided into 3 sections which are marked on the outer border of each page - General Information (pages 2-6),
which applies to both modes of operation, NAPCO Gemini / Ademco Bus Operation (pages 8-12) and Universal Operation
(pages 13-19). After reviewing the General Information section for an overview on the system, refer to the section which applies
to the type of installation at hand, Bus or Universal Operation and follow all indicated steps.
Keyfob Commands
•
Arm / Disarm
•
Stay Mode Arming
•
Panic
•
Garage Door Control
•
Appliance Control 1 / † Relay Group 1 Control
•
Garage 2 or Appliance Control 2/ † Relay Group 2 Control
Keyfob Indicators
•
Armed
•
Armed Stay
•
Armed / Zones Bypassed
•
Disarmed / System Ready
•
Disarmed / Zones Faulted
•
Alarm
•
Alarm Memory
•
Fire Alarm
•
System Trouble
•
KeyFob Low Battery
4
Bus Mode Features
† NAPCO GEM-P3200 & P9600 only
SYSTEM OVERVIEW
Use these tables to determine the Keyfob functionality you
can expect when used on a particular control panel.
Keyfob Commands
•
Arm / Disarm
•
Stay Mode Arming
•
Panic
•
Garage Door Control
Keyfob Indicators
•
Armed / Disarmed
•
Armed Stay
•
Alarm
•
Alarm Memory
•
Fire Alarm
•
KeyFob Low Battery
WI1024B 2WAY-UNIVKF Installation Instructions
Universal Mode Features
Required Control Panel Feature
Keyswitch arm zone or input
(Momentary)
Automatic Interior Bypass
24 hour panic zone
Standard
Required Control Panel Feature
Armed output or lug (high or low)
Automatic Interior Bypass
Steady bell output (high or low)
Steady bell output (high or low)
Pulsing Bell output (high or low)
Standard