Synchronising Time And Date Of The Ip Gateway Card - Panasonic KX-TDA0480 Getting Started Manual

Ip gateway card
Hide thumbs Also See for KX-TDA0480:
Table of Contents

Advertisement

4.6
Synchronising Time and Date of the IP
Gateway Card
Loss of clock synchronisation of the IP Gateway Card will produce alarm indications under 2
conditions: (1) when the IP Gateway Card is newly installed to the Hybrid IP-PBX, or (2) when
it has been disconnected from a power source for more than two months causing the battery
discharge. However the alarm indications do not affect the IP Gateway Card operations, they
should be corrected following the procedure below.
Note
When synchronising time and date, the IP Gateway Card must be connected to a PC (see
2.2.2 10 Base-T Cable Connection). The IP Gateway Card's time and date will be
synchronised with those of the PC with which the card is connected.

4.6 Synchronising Time and Date of the IP Gateway Card

1. Select the desired unit(s), then select "Unit"
"Time sync...".
2. Confirm the unit(s), then click [Execute].
Getting Started
33