Elation PRO HAZE DMX User Instructions page 4

Dmx haze generator
Table of Contents

Advertisement

Pro Haze DMX™
Power Supply:
Before plugging your unit in be sure the source volt-
age in your area matches the required voltage for your Elation
Haze DMX.™ The Elation
Pro Haze DMX
®
230v version. Line voltage may vary from venue to venue, you should
be sure to plug your power supply into a matching wall outlet before
attempting to operate your hazer.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures
and controllers. A DMX controller sends DMX data instructions from
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA "IN" and DATA "OUT" XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA
"OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a single
controller, as long as all fixtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX
fixtures try to use the shortest cable path possible. The order in which
fixtures are connected in a DMX line does not influence the DMX
addressing. For example; a fixture assigned a DMX address of 1 may
be placed anywhere in a DMX line, at the beginning, at the end, or
anywhere in the middle. When a fixture is assigned a DMX address of
1, the DMX controller knows to send DATA assigned to address 1 to
that unit, no matter where it is located in the DMX chain.
Dip-switches in DMX mode: This unit uses dip switches to assign a
DMX address. Each dip switch represents a binary value.
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
Elation Professional
- www.elationlighting.com - Pro Haze DMX™ Instruction Manual Page 7
©
®
Set Up cont.
Pro
®
is available in a 115v and
DMX CHANNEL
2
8
32
128
SP
ON
1
2
3
4
5
6
7
8
9
10
1
4
16
65
256
Pro Haze DMX™
Each dip switch has a preset value. A specific DMX address is set by
combining the dip switches that sum your desired value. For exam-
ple: To achieve a DMX address of 21, combine dip switches 1, 3, and
5. Sense dip switch 1 has a value of 1, dip switch 3 has a value of 4,
and dip switch 5 has a value of 16, the combination of the create a
DMX value of 21.
Set DMX address 21:
Dip-switches # 1 = 1
3 = 4
5 = 16
= 21
Data Cable (DMX Cable) Requirements (For DMX and Master/
Slave Operation):
The Pro Haze DMX can be controlled via DMX-512
protocol. The Elation
Pro Haze DMX™ is a one channel DMX unit. The
®
DMX address is set on the rear panel of the Pro Haze DMX. Your unit and
your DMX controller require a standard 3-pin XLR
connector for data input and data output (Figure
1). If you are making your own cables, be sure to
use standard two conductor shielded cable (This
cable may be purchased at almost all pro sound
and lighting stores). Your cables should be made
with a male and female XLR connector on either
end of the cable. Also remember that DMX cable
must be daisy chained and can not be split.
Notice:
Be sure to follow figures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable's shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR's outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
Elation Professional
- www.elationlighting.com - Pro Haze DMX™ Instruction Manual Page 8
©
®
Set Up cont.
Set DMX address 201:
Dip-switches # 1 = 1
4 = 8
7 = 64
8 = 128
= 201
Figure 1

Advertisement

Table of Contents
loading

Table of Contents