SERVICE MANUAL

Model: HBCW100ABB/HVFE040BBB

8-2-2.Poor cooling
Poor cooling
Check the diaplay temperature
nomber whether it is setted at 18°C
Y
Whether the rear side and the top is
too close to the wall
Y
Whether the cellar is under
sunlight directly
Y
Whether the cellar is near thermal
source
Y
Whether the room temperature is
too hoot or not
Y
Whether the condenser is blocked
by cloth pieces or paper or dirt or
not
Y
Whether the glass door has been
closed well
Y
Whether the glass door door seal
bar is too dirty or sealed well
N
Change to lower
Avoid these
N
matters which
will affect heat
radiation of
condenser and
reduce
refrigeration
ability
N
Frequent opening and extended
opening of glass door will reduce
refrigeration ability
N
Remove dirt and put on a little
N
talcum power
Issue 2011-10-21