Panasonic KX-PRW130W Service Manual page 41

Telephone equipment premium design phone with smartphone connect
Table of Contents

Advertisement

Items
(J)*
Transmitted Power
Confirmation
(L)* Frequency Offset Check
(M)*
Sensitivity Receiver
Confirmation
(N)*
Power RAMP
Confirmation
(O)
Audio Check
(P)
Charging Check
(Q)
TAM Operation
Confirmation
(R)
2.4V Supply
Confirmation VDD2
Check
Point
-
Remove the Antenna before starting step from 1 to 7.
ANTI_TP
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 2
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command "sendchar TST".
3. Execute the command "sendchar dmv 2 2".
4. Check that "Signalling Status" has been set to "Locked", then press "ACCEPT
RFPI".
5. Initiate connection from Dect tester ("set up connect")
6. Execute the command "ANT2".
7. Confirm that the NTP value at ANT is 17.0 dBm ~ 20.0 dBm.
-
Follow steps 1 to 6 of (J).
ANTI_TP
7.Confirm that the frequency offset is < ± 20 kHz.
-
Follow steps 1 to 6 of (J).
ANTI_TP
7.Set DECT tester power to -88 dBm.
8.Confirm that the BER is < 1000 ppm.
-
Follow steps 1 to 6 of (J).
7.Confirm that Power RAMP is matching.
-
1. Link with Handset which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 )/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2 dBm and that the distortion level is <5% at TEL
Line (600  Load).
5. Input -20 dBm (600 )/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -28.0 ± 4 dBm and that the distortion level is <5 % at
Receiver (34  Load).
1. Connect Charge Contact 12 /2 W resistor between charge+ and charge-.
-
2. Measure and confirm voltage across the resistor is 3.9 V ± 0.4 V.
-
1. TAM Confirmation (Execute the command "sendchar VPI").
2. Confirm the returned Value (Value is "JGP7AA 01").
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5V ± 0.1V.
Procedure
41
KX-PRW130W/KX-PRWA13W
Check or
Replace Parts
IC501, C891,
C93, C894,
DA802, Q502,
C525, R507
Refer to (J)
Refer to (J)
Refer to (J)
IC501, SA101,
P101, D101,
Q141, Q142,
R141, R142,
R144, R145,
D141, Q161,
R163, R164,
C171, C173,
R178, C184,
C187
R371, R372,
D362, C351
IC501, IC601,
C60
IC501, Q502,
C525, R507

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-prwa13w

Table of Contents