Nuova Aurelia User Manual

Espresso coffee-maker

Advertisement

Congratulations,
By purchasing the
you have made an excellent choice.
The purchase of a professional espresso coffee-maker involves various elements of selection: the name of the manufacturing firm, the machine's spe-
cific functions, its technical reliability, the option of immediate and suitable servicing, its price. You certainly evaluated all these factors and then made
your choice: the
model.
We think you have made the best choice and after every coffee and cappuccino you will be able to assess this.
You will see how practical, convenient and efficient working with
is.
If this is the first time you have bought a Nuova Simonelli coffee machine, welcome to high quality coffee-making; if you are already a customer of
ours, we feel flattered by the trust you have shown us..
Thanks of the preference.
With best wishes,
Nuova Simonelli s.r.l.
Rel. 02 - 2004
33

Advertisement

Table of Contents
loading

Summary of Contents for Nuova Aurelia

  • Page 1 Congratulations, By purchasing the you have made an excellent choice. The purchase of a professional espresso coffee-maker involves various elements of selection: the name of the manufacturing firm, the machine’s spe- cific functions, its technical reliability, the option of immediate and suitable servicing, its price. You certainly evaluated all these factors and then made your choice: the model.
  • Page 2: Technical Characteristics

    TECHNICAL CHARACTERISTICS 2 Groups 3 Groups 4 Groups NET WEIGHT 74 kg 136 lb 88kg 194 lb 104 kg 229 lb GROS WEIGHT 80kg 176 lb 98 kg 216 lb 120 kg 264 lb POWER 4500 W 4500 W 5000 W 5000 W 5000 W 5000 W...
  • Page 3: Table Of Contents

    ......65 6.1.3 AURELIA VIP-V/ESSE WITH ELECTRONIC DISPLAYS ELECTRIC SYSTEM AURELIA V ..67 (OPTIONAL) .
  • Page 5: Description

    DESCRIPTION Vip Plus - V - Esse Fig. 1 1 Steam knob ESSE version) 9 Filter-holder 2 Programming key (Vip Plus only) 17 Optical level 10 Data plate 3 LCD Display (Vip Plus only) 11 Manual steam nozzle 18 Pressure Gauge 4 Functions buttons (Vip Plus only) 19 Adjustable foot 12 Delivery unit...
  • Page 6: Accessories List

    ACCESSORIES LIST Fig. 2 CODE DESCRIPTION 2 GROUPS 3 GROUPS 4 GROUPS Filling tube ³⁄₈ ” Unit tub draining tube Ø 20 mm - l. 150 cm Worktop draining tube Ø 25 mm - l. 150 cm Filter-holder Double filter Single filter Blind filter Spring...
  • Page 7: Safety Prescription

    SAFETY PRESCRIPTION IlThis book is an integral and essen- RISK OF POLLUTION tial part of the product and must be given to the user. Read this book carefully. It provides important infor- mation concerning safety of installa- tion, use and maintenance. Save it carefully for future reference.
  • Page 8 • do not leave the appliance expo- Basic rules must be observed when If the appliance breaks down or fails sed to atmospheric agents (rain, using any electric appliance. to work properly, switch it off. Any sun, etc.); intervention is strictly forbidden. •...
  • Page 9 CAUTION CAUTION RISK OF POLLUTION RISK OF BURNS OR SCALDING Do not dispose of the machine in the We remind you that before carrying environment: to dispose of the out any installation, maintenance, machine, use an authorised centre, unloading or adjustment operations, or contact the manufacturer for relati- the qualified operator must put on ve information.
  • Page 10: Transport And Handling

    TRANSPORT AND HANDLING MACHINE HANDLING IDENTIFICATION Always quote the machine serial number in all CAUTION communications to the manufacturer, Nuova Simonelli. RISK OF IMPACT OR CRASHING During all handling operations, the operator must ensure that there are no persons, objects or property in the handling area. The pallet must be slowly raised to a height of 30 cm (11,8 in) and moved to the loading area.
  • Page 11: Operations

    INSTALLATION AND PRELIMINARY OPERATIONS Following these operations, connect the plum- power with contact openings of equal dis- After unpacking, assess that the machine and bing systems as illustrated in the following figu- tance or more than 3mm. its accessories unit are complete, then proceed Nuova Simonelli is not liable for any dama- as follows: ge to people or objects due to not observing...
  • Page 12: Qualified Technician Only

    ADJUSTMENTS TO BE MADE BY A QUALIFIED TECHNICIAN ONLY • turn the pump registration screw, turning it PRESSOSTAT/PUMP FILLING BOILER clockwise to INCREASE and counter clock MANUALLY ADJUSTMENT wise to DECREASE the pressure. NOTE: this operation must be carried out with NOTE: this operation can be carried out while the machine turned off.
  • Page 13: Hot Water Economiser Adjustment

    5.4 CLOCK BATTERY PUSH-BUTTON PANEL HOT WATER ECONOMI- REPLACEMENT REPLACEMENT SER ADJUSTMENT (only for the Vip Plus version) The Vip Plus electronic control unit is equipped NOTE: this operation can be carried out while For correct functioning of the machine, perso- the machine is turned on.
  • Page 14: Use

    6.1.1 AURELIA VIP PLUS NOTE: make sure that the general switch is The Aurelia Vip Plus model is provided with always on the position “I”. • Plug the machine in and position the main an optional key management system of wai- The state of the machine will be shown switch on “I”.
  • Page 15: Aurelia V/Esse

    Automatic On/Off PROGRAMMED SPEGNIMENTO: press the RESET key for 6.1.3 AURELIA VIP-V/ESSE WITH 2 seconds; the machine will turn off and ELECTRONIC DISPLAYS (OPTIONAL) NOTE: make sure that the general switch is the display will read OFF always on the position “I”.
  • Page 16: Selection Configuration

    NOTE: when in pause, leave the filter-holder SELECTION MAKING COFFEE inserted in the unit so that it will keep CONFIGURATION warm. To guarantee the utmost thermic stability during use, the delivery units Set the desired function on the available keys Unhitch the filter-holder and fill it with one or are thermo-compensated with comple- placed above the filter-holders (see chapter...
  • Page 17: Making Cappuccino

    MAKING CAPPUCCINO HOT WATER TIMED STEAM NOZZLE SELECTION To obtain the typical cappuccino foam, immer- CAUTION CAUTION se the nozzle all the way into a container 1/3 RISK OF BURNS OR SCALDING RISK OF BURNS OR SCALDING full of milk (preferably cone-shaped). Turn on While steam is being delivered do not touch While using the hot water nozzle, pay care- the steam.
  • Page 18: Programming

    PROGRAMMING into the unit where you intend to carry out and decrease values. AURELIA VIP PLUS the automatic cleaning cycle. Carrying out a cleaning cycle in more than one unit at a ENTER key: to access the menu.
  • Page 19 • Eliminate any residues of PULICAFF from • The display will show the new dose amount probe and the display will read: the blind filter and press the rinsing which can still be changed by means of the cycle starting up key of the unit or units keys STEAM.
  • Page 20 TANDARD DOSES • By pressing the key the display will TRANSFERRING DOSES ENTER read: • When the display reads: • When the display reads: SELECTION TOTAL • All the delivery keys will start to flash on and DOSES TRANSFER PROGRAM DOSES off.
  • Page 21 • Press to confirm and to set the • Use the keys to vary the ENTER MACHINE TOTAL cup-warmer at OFF, which includes from 0 starting up time. to 60 minutes. This indicates the total amount of deliveries • Press to confirm and to go on to ENTER made.
  • Page 22 GRINDING CONTROL PROGRAM- (of the sampled amount) superior to the • Use the keys to set both programmed maximum, the display will values. MING read: • Use the key to confirm. ENTER The Program Vip Plus model is provided FINE GRINDING with an electronic system able to detect deli- Once the set delivery limit or the set main- very parameter variations dependent on...
  • Page 23: Programming Aurelia

    (the other keys will continue AUTOMATIC CUP-WARMER PRO- to flash). PROGRAMMING GRAMMING AURELIA V • Press the continuous key to exit pro- gramming or to continue programming other • Access the programming according to the DOSE PROGRAMMING dose keys.
  • Page 24 LEVELLING PUMP ACTIVATION NOTE: You can set a maximum of five different STANDARD DOSE PROGRAMMING degrees of light intensity. • Access the programming according to the • Setting predetermined values for the four • To store the set light intensity values in the relative procedure.
  • Page 25: Programming Aurelia Esse

    • Access programming according to the rela- tive procedure. • Adjust the light intensity of the keys by pres- In the Aurelia Esse version only the doses of sing the first unit’s 1 long coffee water and timed steam can be programmed.
  • Page 26: Cleaning And Maintenance

    Cleaning the bottom: To clean all the chro- The machine will initiate washing cycle which Aurelia Version Aurelia Version mium-plated areas, use a soft, damp cloth. consists in the circulation of hot water followed...
  • Page 27: Resin And Softener Regeneration

    3) Reposition lever D towards the left (Fig. 39). RESIN AND SOFTENER REGENERATION To avoid scaling deposits in the boiler and in the heating exchangers, the softener must always be kept efficient. Therefore, the ionic resins must be regularly regenerated. Regeneration times are established according Fig.
  • Page 28: Aurelia Plus Machine Function

    AURELIA PLUS MACHINE FUNCTION MESSAGES DISPLAY AND KEY EFFECT SOLUTION CAUSE NOTES INDICATIONS At the time of the diagno- The machine will not sis the system presents heat and all its functions faults within the control will be blocked. DIAGNOSIS OF ERROR unit EPROM.
  • Page 29 DISPLAY AND KEY EFFECT SOLUTION CAUSE NOTES INDICATIONS Switch off the machine The display reading will Incorrect electrical input and send for a specialist flash. The pump will caused by a malfunction technical engineer. switch off. The heating in one of the machine OVERCURRENT ERR.
  • Page 30: Aurelia V Machine Function Messages

    Aurelia V MACHINE FUNCTION MESSAGES DISPLAY AND KEY EFFECT SOLUTION CAUSE NOTES INDICATIONS If the doser doesn’t send If the delivery is not hal- Interrupt the delivery. out its commands within ted manually, the time three sec from the onset limit (120 sec.) will be...
  • Page 31 Aurelia S MACHINE FUNCTION MESSAGES DISPLAY AND KEY EFFECT SOLUTION CAUSE NOTES INDICATIONS If within 90 sec. from The pump, the resistor Turn the machine off for at least 5 sec. and then onset, with pump inser- and all the functions will be halted.
  • Page 32: Electric System Aurelia S

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Aurelia S Fig. 40 LEGENDA/KEY 1 MS Interruttore/ Main Switch. Valve unit 2. Valve unit 3. 2 R Relè/Relay. 8 EV1 Elettrovalvola gruppo 1/Solenoid 12 EVHW Elettrovalvola miscelatore/Solenoid 3 P Pressostato/Pressostat. Valve unit 1. Valve mixer.
  • Page 33: Rel

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Aurelia Plus Rel 3.xx Fig. 41 LEGENDA/KEY Valve unit 2. 12 TP Sonda temperatura/Temperature Probe 1 MS Interruttore/ Main Switch. 8 EV1 Elettrovalvola gruppo 1/Solenoid 13 EVHW Elettrovalvola miscelatore/Solenoid Valve mixer. 2 R Relè/Relay. Valve unit 1.
  • Page 34: Electric System Aurelia Plus Rel 1.Xx

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Aurelia Plus Rel 1.xx Fig. 41 LEGENDA/KEY Valve unit 2. 12 TP Sonda temperatura/Temperature Probe 1 MS Interruttore/ Main Switch. 8 EV1 Elettrovalvola gruppo 1/Solenoid 13 EVHW Elettrovalvola miscelatore/Solenoid Valve mixer. 2 R Relè/Relay. Valve unit 1.
  • Page 35: Electric System Aurelia

    IMPIANTO ELETTRICO /ELECTRIC SYSTEM Aurelia V Fig. 42 LEGENDA/KEY Valve unit 2. 12 TP Sonda temperatura/Temperature Probe 1 MS Interruttore/ Main Switch. 8 EV1 Elettrovalvola gruppo 1/Solenoid 13 EVHW Elettrovalvola miscelatore/Solenoid Valve mixer. 2 R Relè/Relay. Valve unit 1. 9 LP Sonda livello/ level Probe.
  • Page 36: Plumbing System

    IMPIANTO IDRAULICO /PLUMBING SYSTEM Fig. 43 LEGENDA/KEY 7 Rubinetto livello manuale/Manual level fau 14 Valvola di sicurezza cald./Heater safety valve 1 Rubinetto ingresso acqua/Water entrance 8 Livello acqua/Water level 15 Valvola antirisucchio/Anti-suction valve faucet 9 Gruppo erogatore/Delivery unit 16 Economizzatore acqua calda/Hot water 2 Pompa/Pump 10 Pressostato/Pressostat economiser...

Table of Contents