Brigantia 35-DVRS31N User's Installation, Operation And Maintenance Manual

Gas fired vented room heater (direct vent)

Advertisement

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
35-DVRS31N
Gas Fired Vented Room
Heater (Direct Vent)
U
SERS'
O
PERATION and
M
AINTENANCE
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This appliance
is not convertible for use with other gases, unless a
certified kit is used.
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
I
NSTALLATION
*Conversion kit required for Propane use
Tested and
listed by
LABTEST Certification Inc
Richmond, British Columbia
ANSI Z21.88-2009/CSA 2.33-2009
M
ANUAL
200-0035
May 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 35-DVRS31N and is the answer not in the manual?

Questions and answers

Summary of Contents for Brigantia 35-DVRS31N

  • Page 1 35-DVRS31N Gas Fired Vented Room Heater (Direct Vent) SERS’ NSTALLATION PERATION and AINTENANCE ANUAL This appliance may be installed in an aftermarket WARNING: If the information in this manual is permanently located, manufactured home (USA not followed exactly, a fire or explosion may...
  • Page 3  Optional Accessories Check with your Authorized Brigantia Dealer for a full complement of decorative accessories to suit your home’s décor and your tastes.  Electronic Control System The 35-DVR31N uses a gas control valve that is operated by a Supreme Multifunction Remote Control.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Caution and Safety Instructions Appliance Certification, Installation Codes and Specifications Rating Plate Appliance Dimensions and Framing Dimensions Installation Instructions 9-10 Clearance to Combustibles Venting Instructions 11-15 Aeration Adjustment Gas Connections Conversion Kit Instructions 18-19 Final Installation Check and Initial Operation First Fire and Lighting Instructions (CAUTION) Lighting Instructions on Rating Plate Remote Control Setup and Operation...
  • Page 5: Caution And Safety Instructions

    35-DVRS31N CAUTION FOR YOUR SAFETY - Do not install or operate your Brigantia 35-DVR31N without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Brigantia Industries Warranty and may prove hazardous. This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes.
  • Page 6: Appliance Certification, Installation Codes And Specifications

    35-DVRS31N APPLIANCE CERTIFICATION This appliance was listed by LABTEST Certification Inc to the following USA and Canadian gas appliance standards. - ANSI Z21.88-2009/CSA 2.33-2009 Vented Gas Fireplace Heaters - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes -CSA P.4.1-09 testing method for measuring annual fireplace efficiency.
  • Page 7: Rating Plate

    35-DVRS31N RATING PLATE DO NOT REMOVE THIS LABEL NG / NATURAL # de série Serial # LP / PROPANE NE PAS ENLEVER CETTE ÉTIQUETTE 35-DVRS31N MODEL / MODÈLE: LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTI- TUDES.
  • Page 8: Appliance Dimensions And Framing Dimensions

    35-DVRS31N APPLIANCE DIMENSIONS 8 1/2” 216 mm 41 7/8” 1064 mm 34” 864 mm 42 3/8” 1077 mm...
  • Page 9: Installation Instructions

    35-DVRS31N Framing Dimensions Construct the opening to dimensions shown: The following section describes in detail the requirements for framing for the 42 1/2” wide x 42” high model 35-DVRL31N. X 5 1/2” deep 10” 254 mm Note: Framing should be constructed as required by local building codes 11”...
  • Page 10 35-DVRS31N Installation Instructions Cont. Install the wall inside wall portion of the wall thimble Install the nailing flanges provide by screwing them to and seal the entire inside with a high temperature sili- the side of the outer shell using the hole required for cone sealant.
  • Page 11: Clearance To Combustibles

    35-DVRS31N Installation Instructions Cont. VENTING LISTED VENTING SYSTEMS Clearance to combustibles The listed chimney vent systems uses a twist lock The following clearances must be maintained connection. Assemble the vent system using the around the vent pipe: desired combination of sections and elbows for Vertical runs: 1”...
  • Page 12 35-DVRS31N Installation Instructions Cont. Horizontal Wall Vent Terminations When the termination is to be attached to vinyl sid- ing apply a bead of non-hardening mastic around The position of the horizontal vent termination the outside edge to form a seal between the stand- must be positioned in such a way as to meet all off and the terminal.
  • Page 13 35-DVRS31N Installation Instructions Cont. Pitch (Ratio) ‘X’ Vertical Cap Installations Always maintain a 1” clearance around the vent pipe (vertical) and on horizontal venting 2” clearance on the 0/12 - 2/12 4” top of the vent, when passing through ceilings, walls,...
  • Page 14 35-DVRS31N Installation Instructions Cont. Figure 22 – Vent Termination Locations Horizontal Installation Do not install above a meter/regulator assembly within 3 The horizontal run must have a 1/4” rise on an exterior wall and feet (90 cm) horizontally from the centerline of the meter/ regulator.
  • Page 15: Venting Chart

    35-DVRS31N Installation Instructions Cont. Venting Chart Maximum Total NG Venting Length Restrictor Setting #3 Maximum total venting allowed is 45’. Maxi- mum vertical vent is 35’. Maximum horizontal vent is 20’. Minimum 7’ vertical vent rise re- quired for maximum 20’ horizontal vent run.
  • Page 16: Aeration Adjustment

    35-DVRS31N Installation Instructions Cont. AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.
  • Page 17: Gas Connections

    35-DVRS31N GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve.
  • Page 18: Conversion Kit Instructions

    35-DVRS31N CONVERSION KIT INSTRUCTIONS IMPORTANT: This fireplace is Natural gas ready. If converting to LP gas, follow instructions below WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or productions of carbon mon- oxide may result, causing property damage, personal injury or loss of life.
  • Page 19 35-DVRS31N CONVERSION KIT INSTRUCTIONS CONT. CONVERT THE GAS CONTROL VALVE AND REMOTE GAS CONTROL VALVE: Unscrew the threaded regulator cap on the control valve. Press down on pressure regulator tube and rotate 90 degrees. The tube should only come up half way for LP after released and the line should point to LP.
  • Page 20: Final Installation Check And Initial Operation

    35-DVRS31N FINAL INSTALLATION CHECK Each Brigantia Gas Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Brigantia recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and that the electrical system is in working order.
  • Page 21: First Fire And Lighting Instructions (Caution)

    35-DVRS31N FIRST FIRE When operated for the first few times, the appliance will emit some odor and fumes. This is due to the heat from the appliance evaporating the oils and solvents used in fabricating the appliance. Close off the room to the rest of the house and open all windows. Keep the room well ventilated, as smoke alarm may sound.
  • Page 22: Lighting Instructions On Rating Plate

    35-DVRS31N LIGHTING INSTRUCTIONS ON RATING PLATE...
  • Page 23: Remote Control Setup And Operation

    35-DVRS31N REMOTE CONTROL SETUP AND OPERATION...
  • Page 24 35-DVRS31N REMOTE CONTROL SETUP AND OPERATION CONT.
  • Page 25 35-DVRS31N REMOTE CONTROL SETUP AND OPERATION CONT.
  • Page 26 35-DVRS31N REMOTE CONTROL SETUP AND OPERATION CONT.
  • Page 27 35-DVRS31N REMOTE CONTROL SETUP AND OPERATION CONT.
  • Page 28: Maintenance And Cleaning The Appliance

    Regularly:  Frequent cleaning of the ceramic glass is required. Brigantia recommends using a good quality “gas fireplace” glass cleaner that is available at any hearth retail location. DO NOT CLEAN WHILE HOT.
  • Page 29: Component Removal

    35-DVRS31N Component Removal NOTE: Do not remove any components while the appliance is hot. Surround Removal The surround is held in place by clips buttons (two at the top, two at the bottom). Grasp the surround by the sides and pull, releasing the clips.
  • Page 30 35-DVRS31N Component Removal Baffle Removal Carefully slide the baffle to the Right and- lower the free side down until the baffle end clears the firebox side, gently slid out the opposite end to remove. Plaque Removal Tilt plaque forward till the top edge clears the top of the firebox and grasp sides to lift out.
  • Page 31: Servicing Under Warranty

    35-DVRS31N SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Brigantia warranty at the back of the manual. Contact the authorized Brigantia dealer where you purchased the appliance from and provide them with details of the problem, along with the initial installation information (from the front of this manual).
  • Page 32: Checking Inlet/Outlet Gas Pressures, Adjusting Pilot And Convertible Pilot Orifice

    35-DVRS31N CHECKING INLET AND OUTLET GAS PRESSURE 1. Remove the surround. 2. The pressure test taps are located on the valve. The taps are located in the gas valve front face. The inlet is marked ‘IN’ and the outlet is marked ‘OUT’. See Fig.1.
  • Page 33: Wiring Schematics

    35-DVRS31N WIRING SCHEMATICS...
  • Page 34: Warranty

    This Limited Warranty is made by BRIGANTIA FIREPLACES, hereinafter referred to as “Brigantia”. Brigantia warrants to the original purchaser of an Brigantia gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use and service, for a “lifetime”.
  • Page 35: Frequently Asked Questions

    Q. My fan/blower makes a “whirring” or “humming” noise. A. Your Brigantia gas appliance uses a powerful fan to push heated air into your room. It is not unusual to hear a “humming” noise when your fan is running. Note: the sound will change depending on the set- ting that your fan speed control is set at.
  • Page 36: Notes

    35-DVRS31N NOTES...
  • Page 37 35-DVRS31N NOTES...
  • Page 38: Warranty Registration Card

    POSTAGE WARRANTY REGISTRATION BRIGANTIA FIREPLACES 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED 35-DVRS31N Model # : Serial #: Date Installed: yyyy Name: Address: City: State/Prov: ZIP: Phone: ( _____ ) Dealer's Name &...
  • Page 39 BRIGANTIA FIREPLACES 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.Brigantia.com...