Burner Pressure and gas rate
Burner Pressure thermoCOMPACT 615/2 E
Gas type
Natural gas 2H
Main burner jet mark
2)
7 / 120
LPG 3 B/P
Main burner jet mark
2)
7 / 072
Burner Pressure thermoCOMPACT 620/2 E
Gas type
Natural gas 2H
Main burner jet mark
2)
7 / 120
LPG 3 B/P
Main burner jet mark
2)
7 / 072
Burner Pressure thermoCOMPACT 624/2 E, turboMAX plus 824/2 E
Gas type
Natural gas 2H
Main burner jet mark
2)
7 / 120
LPG 3 B/P
Main burner jet mark
2)
7 / 072
Burner Pressure thermoCOMPACT 628/2 E, turboMAX plus 828/2 E
Gas type
Natural gas 2H
Main burner jet mark
2)
7 / 120
LPG 3 B/P
Main burner jet mark
2)
7 / 072
Table 7.1: Burner pressure
1) 15 °C, 1013mbar, dry
2) The nozzles are stamped with the mark shown in this table. The
marking corresponds to the nozzle hole diameter multiplied by 100
Instructions for Installation and Servicing turboMAX plus and thermoCOMPACT R1
Supplied By www.heating spares.co Tel. 0161 620 6677
Gas supply adjustments (Commissioning Part II) 7
Burner pressure
[mbar]
1)
for G20
Burner pressure
[mbar]
1)
for G30
for G31
Burner pressure
[mbar]
1)
for G20
Burner pressure
[mbar]
1)
for G30
for G31
Ignition rate 8.9 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0
Burner pressure
[mbar]
1)
1.9
for G20
Burner pressure
[mbar]
1)
for G30
3.9
for G31
5.2
Ignition rate 10.4 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0
Burner pressure
[mbar]
1)
1.8
for G20
Burner pressure
[mbar]
1)
for G30
4.1
for G31
5.5
Ignition rate
6.5
2.2
2.2
4.1
4.1
5.8
5.8
Ignition rate 7.7
8.0
10.0 12.0
1.5
1.5
1.6
2.4
2.0
2.0
3.2
5.0
4.3
4.3
4.5
71
1.9
2.1
2.9
3.7
3.9 4.8
6.8 9.0
5.2 6.4
8.8 11.6
1.8
2.3
3.0
3.9
4.1
5.3
7.1
9.0
5.5 7.1
9.5
12.1
Output[kW]
8.0
10.0
12.0
14.0
15.0
3.2
4.7
6.6
8.7
9.9
6.2
9.6
13.6
18.1
20.6
8.7
13.3
18.7
24.9
28.3
Output[kW]
14.0 16.0 18.0
20.0
3.4
4.6
5.9
7.4
9.0
7.3
9.9
12.8
16.1
19.7
10.1
13.7
17.6
22.0
26.9
Output[kW]
4.7
5.8
6.7
8.4
9.8
11.6
14.3 17.4
20.6
24.1
14.8 18.3 22.1
26.2
30.6
Output[kW]
4.8 5.8
6.8
8.0
9.2
11.2 13.5 16.1
18.8 21.7
15.0 18.1
21.6
25.2 29.1
10.5
24.8
33.2
31