  • Page 1 ZENOTEC Air Instructions for Use iVT16-912 (120 volt) & iVT25-912(230 volt)
  • Page 2: Principle Of Operation

    1- INTRODUCTION You are now the owner of a Quatro IVac System, an advanced effective indoor air purification system designed specifically to remove particulate matter. You can expect a noticeable improvement in air quality as the IVac begins the process of reducing microscopic airborne particulate. PRINCIPLE OF OPERATION The iVAC features a four step AUTOMATIC method of operation: a) rear knockout chamber forces heavier particles to the tray;...
  • Page 3: Important Installation Instructions

    Insert male end of power cord into grounded circuit of the proper voltage and that can handle the system amperage. b) Plug in the supplied remote cable to the iVac & the Wieland Zenotec Milling Machine. c) Start a process on the Zenotech Milling Machine. The iVac will start up by itself when it receives the 24VDC control signal from the Zenotec milling machine system d) Adjust fan speed controls to the minimum required airflow.
  • Page 4: Automatic Filter Cleaning

    7- i Series Controls Our “i Series” Controls feature soft touch On/Off, Speed Up & Speed Down Buttons and a remote operation interface. It also features a visual and audible alarm system for the filters and the blower motors should service be required. The i-Series controls are equipped with an “Autoflow” pressure compensation feature.
  • Page 5 Light Diagnostics Table D10-8 & C10-8 Light Led 1 Led 2 Led 3 Led 4 Led 5 Audible Condition Action Alert System Illuminated None Unit is operating using POWER button Operation FULLY on panel, no remote signal Illuminated Illuminated None Unit is operating using remote signal FULLY FULLY...
  • Page 6 IN-OUT FULLY Vacuum Controlled By Remote or mc2 Vaccum , Cleans & The ReStarts Vaccum...
  • Page 7 8- IVac i Series Specifications Description iVT16-912 iVT25-912 Approximate Dimensions: 29”h x 16”w x 20”d 29”h x 16”w x 20”d Voltage, current 120/1/60, 12.8 amps 230/1/50,8 amps Approx. Weight: 85lbs 85lbs 9- General Maintainence & Inspection Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures ensuring the unit will provide trouble-free operation for years to come.
  • Page 8: Troubleshooting Guide

    11- MOTOR SERVICE BLOWER MAINTENANCE, CHANGING BRUSHES This unit is also equipped with an Automatic Motor and Brush Optimization System. To optimize motor life, motor brushes need to be monitored and replaced PRIOR TO BEING WORN RIGHT OWN TO THE BASE. If brush is worn to the base, there is HIGH RISK of brush damaging the motor. If this happens, you will require replacement of entire motor.
  • Page 9: Warranty

    Unit Will Not Start Faulty Power Supply Check Breaker Box Control Panel Circuit Breaker Tripped Reset Circuit Breaker Unit Not Plugged Into Receptacle Plug Unit In Excessive Pressure Change filters, look for system blockage Hose Blocked Remove Obstruction Unit Starts,Then Stops Particulate Filter Blocked Check For Proper Installation Of Filters Filter Not Installed...
  • Page 10 WIELAND offers a wide range of products and services from CAD / CAM technologies and dental alloys to veneering ceramics and electroforming. Thanks to our worldwide presence and international network, WIELAND is never far away, and your contact person can always be located via the Internet.